Liquid ultraviolet matrix-assisted laser desorption/ionization mass spectrometry for automated proteomic analysis

被引:33
作者
Cramer, R
Corless, S
机构
[1] Ludwig Inst Canc Res, London W1P 8BT, England
[2] UCL, Dept Biochem & Mol Biol, London, England
关键词
mass spectrometry; liquid matrix; ultraviolet matrix-assisted laser desorption; ionization;
D O I
10.1002/pmic.200400956
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have combined several key sample preparation steps for the use of a liquid matrix system to provide high analytical sensitivity in automated ultraviolet - matrix-assisted laser desorption/ ionisation - mass spectrometry (UV-MALDI-MS). This new sample preparation protocol employs a matrix-mixture which is based on the glycerol matrix-mixture described by Sze et al. U. Am. Soc. Mass Spectrom. 1998, 9, 166-174). The low-ferntomole sensitivity that is achievable with this new preparation protocol enables proteomic analysis of protein digests comparable to solid-state matrix systems. For automated data acquisition and analysis, the MALDI performance of this liquid matrix surpasses the conventional solid-state MALDI matrices. Besides the inherent general advantages of liquid samples for automated sample preparation and data acquisition the use of the presented liquid matrix significantly reduces the extent of unspecific ion signals in peptide mass fingerprints compared to typically used solid matrices, such as 2,5-dihydrox-ybenzoic acid (DHB) or alpha-cyano-hydroxycinnamic acid (CHCA). In particular, matrix and lowmass ion signals and ion signals resulting from cation adduct formation are dramatically reduced. Consequently, the confidence level of protein identification by peptide mass mapping of in-solution and in-gel digests is generally higher.
引用
收藏
页码:360 / 370
页数:11
相关论文
共 55 条
[1]   Ionic liquids as matrixes for matrix-assisted laser desorption/ionization mass spectrometry [J].
Armstrong, DW ;
Zhang, LK ;
He, LF ;
Gross, ML .
ANALYTICAL CHEMISTRY, 2001, 73 (15) :3679-3686
[2]  
Berkenkamp S, 1997, RAPID COMMUN MASS SP, V11, P1399
[3]   Wall-less sample preparation of μm-sized sample spots for femtomole detection limits of proteins from liquid based UV-MALDI matrices [J].
Bogan, MJ ;
Agnes, GR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2004, 15 (04) :486-495
[4]   Ionic matrices for matrix-assisted laser desorption/ionization time-of-flight detection of DNA oligomers [J].
Carda-Broch, S ;
Berthod, A ;
Armstrong, DW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (06) :553-560
[5]  
CHAN TWD, 1994, CHEM PHYS LETT, V222, P579, DOI 10.1016/0009-2614(94)00385-8
[6]   Accurate mass measurements for peptide and protein mixtures by using matrix-assisted laser desorption/ionization Fourier transform mass spectrometry [J].
Chan, TWD ;
Duan, L ;
Sze, TPE .
ANALYTICAL CHEMISTRY, 2002, 74 (20) :5282-5289
[7]  
Cramer R, 2000, RAPID COMMUN MASS SP, V14, P53
[8]   Graphite/liquid mixed matrices for laser desorption/ionization mass spectrometry [J].
Dale, MJ ;
Knochenmuss, R ;
Zenobi, R .
ANALYTICAL CHEMISTRY, 1996, 68 (19) :3321-3329
[9]   Fundamentals of matrix-assisted laser desorption/ionization mass spectrometry with pulsed infrared lasers [J].
Dreisewerd, K ;
Berkenkamp, S ;
Leisner, A ;
Rohlfing, A ;
Menzel, C .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2003, 226 (01) :189-209
[10]  
Fujita T, 1997, RAPID COMMUN MASS SP, V11, P1115, DOI 10.1002/(SICI)1097-0231(19970630)11:10<1115::AID-RCM908>3.0.CO