Spectroscopic investigation on the impurity influxes of carbon and silicon in the ASDEX upgrade experiment

被引:17
作者
Pugno, P [1 ]
Kallenbach, A [1 ]
Bolshukhin, D [1 ]
Dux, R [1 ]
Gafert, J [1 ]
Neu, R [1 ]
Rohde, V [1 ]
Schmidtmann, K [1 ]
Ullrich, W [1 ]
Wenzel, U [1 ]
机构
[1] Max Planck Inst Plasmaphys, IPP, EURATOM Assoc, D-85748 Garching, Germany
关键词
plasma facing components; spectroscopy; siliconization;
D O I
10.1016/S0022-3115(00)00633-4
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Emission profiles of carbon and silicon along the heat shield (HS) were measured before and after siliconization of the vessel. Siliconization does not affect the divertor and therefore large changes in impurity concentrations and influxes cannot be attributed to it. A strong transient increase of the silicon concentration was observed immediately after the siliconization lasting for a few discharges. However, no large change was observed in the silicon influx from the HS, excluding it as possible source of the concentration increase. The fast decrease in the silicon concentration can be attributed to strong erosion at the outer limiter. The impurity influxes for C2+ and Si2+ from the HS ale estimated and compared with the corresponding core concentrations. The relative contribution to the plasma impurity content from divertor, HS and outer protection limiter is discussed. Zeeman splitting analysis permits one to identify the emitting region of carbon radiation. Anomalously high silicon sputtering yields are measured, which do not however cause high core silicon content. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:308 / 311
页数:4
相关论文
共 13 条
[1]   Z dependence of the core impurity transport in ASDEX Upgrade H mode discharges [J].
Dux, R ;
Peeters, AG ;
Gude, A ;
Kallenbach, A ;
Neu, R .
NUCLEAR FUSION, 1999, 39 (11) :1509-1522
[2]   A spatially scanning vacuum ultraviolet and visible range spectrometer for spectroscopy of tokamak plasmas in ASDEX-Upgrade [J].
Field, AR ;
Fink, J ;
Dux, R ;
Fussmann, G ;
Wenzel, U ;
Schumacher, U .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (12) :5433-5441
[3]   A comparison of impurity screening between limiter and divertor plasmas in the Alcator C-Mod tokamak [J].
Granetz, RS ;
McCracken, GM ;
Bombarda, F ;
Goetz, JA ;
Jablonski, D ;
LaBombard, B ;
Lipschultz, B ;
Ohkawa, H ;
Rice, JE ;
Terry, JL ;
Wang, Y .
JOURNAL OF NUCLEAR MATERIALS, 1997, 241 :788-792
[4]   Effects of divertor geometry and chemical sputtering on impurity behaviour and plasma performance in JET [J].
Guo, HY ;
Matthews, GF ;
Coffey, I ;
Erents, SK ;
Groth, M ;
Harbour, PJ ;
von Hellermann, MG ;
Hillis, DL ;
Hogan, JT ;
Horton, LD ;
Ingesson, LC ;
Lawson, KD ;
Lingertat, J ;
Maggi, CF ;
McCracken, GM ;
Monk, RD ;
Morgan, PD ;
Stamp, MF ;
Stangeby, PC ;
Taroni, A ;
Vlases, GC .
NUCLEAR FUSION, 2000, 40 (03) :379-396
[5]   EXPERIMENTAL MEASUREMENTS OF THE FUELING EFFICIENCY OF IMPURITIES INJECTED INTO TEXTOR [J].
MCCRACKEN, GM ;
SAMM, U ;
STANGEBY, PC ;
BERTSCHINGER, G ;
BOEDO, JA ;
DAVIES, SJ ;
GRAY, DS ;
PHILIPPS, V ;
PITTS, RA ;
GOODALL, DHJ ;
POSPIESZCZYK, A ;
SCHORN, RP ;
SCHWEER, B ;
TELESCA, G ;
UNTERBERG, B ;
WAIDMANN, G .
NUCLEAR FUSION, 1993, 33 (10) :1409-1425
[6]   Studies in JET diverters of varied geometry.: III:: Intrinsic impurity behaviour [J].
McCracken, GM ;
Barnsley, R ;
Guo, HY ;
von Hellermann, MG ;
Horton, LD ;
Jäckel, HJ ;
Lingertat, J ;
Maggi, CF ;
Matthews, GF ;
Monk, RD ;
O'Mullane, MG ;
Stamp, MF ;
Stangeby, PC ;
Vlases, GC ;
Zastrow, KD .
NUCLEAR FUSION, 1999, 39 (01) :41-60
[7]  
NEU R, 1995, P 22 EPS C CONTR F C, V19, P1065
[8]  
PHILIPPS V, 1999, P 26 EPS C CONTR F J, V23, P713
[9]  
RHODE V, 1999, P 26 EPS C CONTR F J, V23, P1513
[10]   IMPURITY PRODUCTION AND TRANSPORT IN THE DIVERTOR TOKAMAK ASDEX [J].
ROTH, J ;
JANESCHITZ, G .
NUCLEAR FUSION, 1989, 29 (06) :915-935