Determination of erythema-effective solar radiation in Japan and Germany with a spore monolayer film optimized for the detection of UVB and UVA - results of a field campaign

被引:47
作者
Furusawa, Y
Quintern, LE
Holtschmidt, H
Koepke, P
Saito, M
机构
[1] BioSense, Lab Biosensory Syst, D-53332 Bornheim, Germany
[2] Natl Inst Radiol Sci, Space & Particle Radiat Sci Res Grp, Chiba 263, Japan
[3] Univ Munich, Inst Meteorol, D-80333 Munich, Germany
关键词
D O I
10.1007/s002530051341
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The available physical and biological broadband radiometers designed to determine erythema-effective radiation do not show any response or over/underestimate the biologically effective radiation to a high extent in the ultraviolet (UV)A spectral region. The data presented in this paper demonstrate that the biological system used in this study is the first one to make possible measurements of erythema-effective radiation in the sun in the UVA and WE spectral region. These measurements were performed with a spore-film filter system as well as with spectroradiometers. It was demonstrated that this biotechnological method could be used to determine exact values expressed as minimal erythemal dose (MED). The spore-film system was tested in various field campaigns performed in Germany and in Japan. The seasonal daily variation of UV radiation in Germany determined in the period November 1995 to December 1996 using the spore-film filter system in sunny conditions tallied well with model calculations. The daily dose in Germany measured with the spore-film system close to the summer solstice, in sunny conditions (20.45 MED), was approximately 20 times higher than the lowest value measured close to the winter solstice (0.82 MED), a result which was in accordance with model calculations. The data determined with the spore-film filter system in Sapporo and Naha, Japan, fitted to the erythema-weighted data calculated from spectroradiometric measurements (Brewer), even at low solar radiation angles in a solar spectrum with less UVB but significant UVA. The spore-film dosimeter values were about 103 +/- 8% of the integrated dose of the Brewer instrument. The standard deviation of the spore-film measurements obtained in Japan was 12.8%. The responsivity of the spore-film system towards longer wavelengths within the UVA spectrum was tested with the Okasaki Large Spectrograph with monochromatic radiation. At a wavelength of 365 nm - in a spectral region which is dominant in many tanning lamps and with minor importance for solar radiation in summer conditions - the tested spore-film system gave results that were close (112% compared to the calibration dose) to the calibration dose which was used for irradiation.
引用
收藏
页码:597 / 603
页数:7
相关论文
共 19 条
[1]  
DEGRUIJL FR, 1993, CANCER RES, V53, P53
[2]   BIOLOGICAL AND PHYSICAL DOSIMETERS FOR MONITORING SOLAR UV-B LIGHT [J].
FURUSAWA, Y ;
SUZUKI, K ;
SASAKI, M .
JOURNAL OF RADIATION RESEARCH, 1990, 31 (02) :189-206
[3]   Quantification of the biological effectiveness of environmental UV radiation [J].
Horneck, G .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 1995, 31 (1-2) :43-49
[4]  
*INT RAD PROT ASS, 1989, HLTH PHYSICS, V49, P331
[5]  
ITO T, 1995, FRONTIERS PHOTOBIOLO, P515
[6]  
ITO T, 1991, J METEOROL RES, V43, P213
[7]  
JAGGER J, 1985, SOLAR UV ACTIONS LIV
[8]  
McKinlay A. F., 1987, CIE J, V6, P17
[9]   Experimental correspondence between spore dosimetry and spectral photometry of solar ultraviolet radiation [J].
Munakata, N ;
Morohoshi, F ;
Hieda, K ;
Suzuki, K ;
Furusawa, Y ;
Shimura, H ;
Ito, T .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1996, 63 (01) :74-78
[10]   Characterization and application of UV detector spore films: The sensitivity curve of a new detector system provides good similarity to the action spectrum for UV-induced erythema in human skin [J].
Quintern, LE ;
Furusawa, Y ;
Fukutsu, K ;
Holtschmidt, H .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 1997, 37 (1-2) :158-166