Automated static perimetry: The influence of myopia and its method of correction

被引:60
作者
Aung, T
Foster, PJ
Seah, SK
Chan, SP
Lim, WK
Wu, HM
Lim, ATH
Lee, L
Chew, SJ
机构
[1] Singapore Natl Eye Ctr, Singapore 168751, Singapore
[2] Def Med Res Inst, Singapore, Singapore
[3] Singapore Eye Res Inst, Singapore, Singapore
[4] UCL, Inst Ophthalmol, London, England
[5] Tan Tock Seng Hosp, Singapore, Singapore
关键词
D O I
10.1016/S0161-6420(00)00497-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives To determine how the magnitude of myopia and its method of correction influence visual field testing. Design: Prospective observational case series, including comparison of spectacles and contact lenses. Participants: One hundred forty-six ophthalmologically normal males 19 to 24 years of age with myopia (spherical equivalent from -0.50 to -14.0 diopters). Methods: Participants performed automated static threshold perimetry. Refractive errors were corrected using trial lenses and soft contact lenses. Subjects were tested with both methods of correction, the order of which was randomized. Main Outcome Measures: Threshold sensitivity and global indexes. Results: Only one subject (0.7%) had a significant reproducible visual field defect on both methods of correction. Six subjects (4.1%) had a focal visual field defect on one method of correction but not the other. For myopia greater than -4.0 diopters, the mean defect decreased significantly as axial length and degree of myopia increased (P < 0.01). Similar results were obtained with either method of correction. Conclusions: Threshold sensitivity is reduced in moderate and high myopia, regardless of the method of correction. The surprisingly low prevalence of visual field defects in this myopic population disputes the widely held view that myopia is associated commonly with visual field abnormalities. if field defects are found in myopes on automated perimetry, it is advisable to repeat the test with another method of optical correction to check that such defects are genuine and not related to the method of refractive correction. Ophthalmology 2001;108: 290-295 (C) 2001 by the American Academy of Ophthalmology.
引用
收藏
页码:290 / 295
页数:6
相关论文
共 23 条
[1]   APPLANATION OCULAR TENSION IN MYOPIA AND EMMETROPIA [J].
ABDALLA, MI ;
HAMDI, M .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1970, 54 (02) :122-&
[2]   THRESHOLD PERIMETRY IN TILTED DISK SYNDROME [J].
BRAZITIKOS, PD ;
SAFRAN, AB ;
SIMONA, F ;
ZULAUF, M .
ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (12) :1698-1700
[3]   ATYPICAL NERVE-FIBER LAYER DEFECTS IN HIGH MYOPES WITH HIGH-TENSION GLAUCOMA [J].
CHIHARA, E ;
SAWADA, A .
ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (02) :228-232
[4]  
DAUBS JG, 1981, T OPHTHAL SOC UK, V101, P121
[5]  
DAVID R, 1985, ARCH OPHTHALMOL-CHIC, V103, P1812
[6]   Histomorphometry of the optic disc in highly myopic eyes with absolute secondary angle closure glaucoma [J].
Dichtl, A ;
Jonas, JB ;
Naumann, GOH .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (03) :286-289
[7]  
Eong K. G. Au, 1993, Singapore Medical Journal, V34, P489
[8]  
Eong K. G. Au, 1993, Singapore Medical Journal, V34, P29
[9]   MYOPIA AND GLAUCOMA [J].
GREVE, EL ;
FURUNO, F .
ALBRECHT VON GRAEFES ARCHIV FUR KLINISCHE UND EXPERIMENTELLE OPHTHALMOLOGIE, 1980, 213 (01) :33-41
[10]   Optic disc morphology in myopic primary open-angle glaucoma [J].
Jonas, JB ;
Dichtl, A .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1997, 235 (10) :627-633