Carotid MR angiography: Phase II study of safety and efficacy for MS-325

被引:56
作者
Bluemke, DA
Stillman, AE
Bis, KG
Grist, TM
Baum, RA
D'Agostino, R
Malden, ES
Pierro, JA
Yucel, EK
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21287 USA
[2] Cleveland Clin, Dept Radiol, Cleveland, OH USA
[3] William Beaumont Hosp, Dept Radiol, Royal Oak, MI 48072 USA
[4] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[5] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[6] Univ Vermont, Dept Radiol, Fletcher Allen Hlth Care, Burlington, VT 05405 USA
[7] Washington Univ, Med Ctr, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[8] EPIX Med, Cambridge, MA USA
关键词
carotid arteries; MR; stenosis or obstruction; contrast media; experimental studies; magnetic resonance (MR); vascular studies;
D O I
10.1148/radiology.219.1.r01ap42114
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the safety and efficacy of MS-325 in patients suspected of having carotid arterial disease. MATERIALS AND METHODS: Fifty carotid arteries in 26 patients were imaged with three-dimensional spoiled gradient-recalled-echo magnetic resonance (MR) angiography at 5 and 50 minutes after injection of MS-325. MS-325 was administered intravenously as a single dose of 0.01, 0.03, or 0.05 mmol per kilogram of body weight as determined with a dose randomization scheme for four, nine, and 13 patients, respectively. Safety, including clinical laboratory changes and electrocardiographic monitoring, was assessed until approximately 3 days after injection. Conventional contrast agent-enhanced angiography was used as the standard of reference. Independent readers blinded to the dose interpreted the MR angiographic and conventional images. Images were assessed for location and extent of carotid arterial stenosis. RESULTS: There were no severe or serious adverse events. For the determination of clinically significant stenosis (>70%) on the 5-minute images, sensitivity, specificity, and accuracy (P = .07, three-way comparison) were 100%, 100%, and 100%; 63%, 100%, and 88%; and 40%, 75%, and 55% at 0.01, 0.03, and 0.05 mmol/kg, respectively. Sensitivity and specificity for images at 50 minutes after MS-325 administration showed the same trends as the 5-minute images. CONCLUSION: Overall accuracy for MS-325-enhanced carotid MR angiography performed during steady-state conditions of circulating contrast agent approximately 5 minutes after injection was high (88%-100%) at 0.03 and 0.61 mmol/kg. MS-325 was well tolerated at all evaluated doses.
引用
收藏
页码:114 / 122
页数:9
相关论文
共 34 条
[21]   DYNAMIC GADOLINIUM-ENHANCED 3-DIMENSIONAL ABDOMINAL MR ARTERIOGRAPHY [J].
PRINCE, MR ;
YUCEL, EK ;
KAUFMAN, JA ;
HARRISON, DC ;
GELLER, SC .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (06) :877-881
[22]   Carotid artery stenosis, occlusion, and pseudo-occlusion: First-pass, gadolinium-enhanced, three-dimensional MR angiography - Preliminary study [J].
Remonda, L ;
Heid, O ;
Schroth, G .
RADIOLOGY, 1998, 209 (01) :95-102
[23]   Gadolinium-enhanced MR angiography of the carotid arteries: A. small step, a giant leap? [J].
Rofsky, NM ;
Adelman, MA .
RADIOLOGY, 1998, 209 (01) :31-34
[24]   MR angiography in carotid stenosis: A comparison of three techniques [J].
Scarabino, T ;
Carriero, A ;
Magarelli, N ;
Florio, F ;
Giannatempo, GM ;
Bonomo, L ;
Salvolini, U .
EUROPEAN JOURNAL OF RADIOLOGY, 1998, 28 (02) :117-125
[25]  
Scarabino T, 1999, J NEURORADIOLOGY, V26, P87
[26]   VOLUME MR ANGIOGRAPHY - METHODS TO ACHIEVE VERY SHORT ECHO TIMES [J].
SCHMALBROCK, P ;
YUAN, C ;
CHAKERES, DW ;
KOHLI, J ;
PELC, NJ .
RADIOLOGY, 1990, 175 (03) :861-865
[27]   Extracranial atherosclerotic carotid artery disease: Evaluation of non-breath-hold three-dimensional gadolinium-enhanced MR angiography [J].
Slosman, F ;
Stolpen, AH ;
Lexa, FJ ;
Schnall, MD ;
Langlotz, CP ;
Carpenter, JP ;
Goldberg, HI .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) :489-495
[28]   Clinical integration of three-dimensional helical CT angiography into academic radiology: Results of a focused survey [J].
Smith, PA ;
Fishman, EK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (02) :445-447
[29]  
Stuber M, 1999, J MAGN RESON IMAGING, V10, P790, DOI 10.1002/(SICI)1522-2586(199911)10:5<790::AID-JMRI25>3.0.CO
[30]  
2-I