Clinical comparison of the measurement of the IOP with the ocular blood flow tonometer, the Tonopen XL and the Goldmann applanation tonometer

被引:35
作者
Bafa, M
Lambrinakis, I
Dayan, M
Birch, M
机构
[1] Royal Victoria Infirm, Glaucoma Clin, Newcastle Upon Tyne NE1 4LP, Tyne & Wear, England
[2] Athens Eye Hosp, Athens, Greece
来源
ACTA OPHTHALMOLOGICA SCANDINAVICA | 2001年 / 79卷 / 01期
关键词
ocular blood flow tonometer; Tonopen XL; Goldmann applanation tonometer; clinical comparison;
D O I
10.1034/j.1600-0420.2001.079001015.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: In addition to measuring ocular blood flow, the ocular blood flow tonometer (OBF) can also be set to solely record intraocular pressure (IOP), In this mode it provides a quick means of tonometry which may allow nursing staff to be more easily trained in its use than conventional Goldmann tonometry, With a view to its eventual use in nurse-led clinics we undertook a study to compare both the OBF tonometer and our currently favoured nurse practitioners tonometer the tonopen XL with Goldmann tonometry, Method: IOP was measured in 99 eyes with all three tonometers in a random order. Results: There was not any statistically significant difference between the measurements of all three tonometers, Conclusions: It is concluded that OBF tonometer can provide clinically useful measurements of intraocular pressure which may in fact be more accurate than the tonopen, however, our opinion is that it possibly is not suitable for a universal glaucoma clinics application.
引用
收藏
页码:15 / 18
页数:4
相关论文
共 17 条
[1]   EVALUATION OF THE TONO-PEN AND THE PULSAIR TONOMETERS [J].
ARMSTRONG, TA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1990, 109 (06) :716-720
[2]   THE TONO-PEN - A MANOMETRIC AND CLINICAL-STUDY [J].
BOOTHE, WA ;
LEE, DA ;
PANEK, WC ;
PETTIT, TH .
ARCHIVES OF OPHTHALMOLOGY, 1988, 106 (09) :1214-1217
[3]  
BORDON AF, 1995, J PEDIATR OPHTHALMOL, V32, P373
[4]  
CHRISTOFFERSEN T, 1993, ACTA OPHTHALMOL, V71, P103
[5]   EVALUATION OF THE TONO-PEN-2 AND THE X-PERT(TM) NONCONTACT TONOMETERS IN CATARACT-SURGERY [J].
DENIS, P ;
NORDMANN, JP ;
BERTIN, V ;
GAYRAUD, JM ;
LAROCHE, L ;
SARAUX, H .
OPHTHALMOLOGICA, 1993, 207 (03) :155-161
[6]   Tonometry in adults and children -: A manometric evaluation of pneumatonometry, applanation, and TonoPen in vitro and in vivo [J].
Eisenberg, DL ;
Sherman, BG ;
McKeown, CA ;
Schuman, JS .
OPHTHALMOLOGY, 1998, 105 (07) :1173-1181
[7]   AN EVALUATION OF THE TONO-PEN FOR THE MEASUREMENT OF DIURNAL INTRAOCULAR-PRESSURE [J].
FARRAR, SM ;
MILLER, KN ;
SHIELDS, MB ;
STOUP, CM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 107 (04) :411-416
[8]   TONO-PEN TONOMETRY IN NORMAL AND IN POSTKERATOPLASTY EYES [J].
GEYER, O ;
MAYRON, Y ;
LOEWENSTEIN, A ;
NEUDORFER, M ;
ROTHKOFF, L ;
LAZAR, M .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1992, 76 (09) :538-540
[9]   COMPARISON OF INTRAOCULAR-PRESSURE MEASUREMENTS WITH THE OCULAB TONO-PEN VS MANOMETRY IN HUMANS SHORTLY AFTER DEATH [J].
HESSEMER, V ;
ROSSLER, R ;
JACOBI, KW .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1988, 105 (06) :678-682
[10]  
HINES MW, 1988, AM J OPHTHALMOL, V106, P174