Dynamic voltage support planning for receiving end power systems based on evaluation of state separating and transferring risks

被引:13
作者
Zhang, Yong-jun [1 ]
Chen, Chao [1 ]
Li, Yong [2 ]
Wu, Guo-bing [3 ]
机构
[1] S China Univ Technol, Coll Elect Power, Guangzhou 510640, Peoples R China
[2] Guangdong Elect Power Design Inst, Guangzhou 510663, Guangdong, Peoples R China
[3] Guangdong Power Dispatch Ctr, Guangzhou 510600, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Dynamic voltage support; Receiving end; Voltage stability; Risk; State separating; State transferring;
D O I
10.1016/j.epsr.2010.06.016
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a novel optimization model of dynamic voltage support planning. It considers the state transition course after great disturbance of large-scale receiving end networks (REN). The risk of contingency can be equivalent to the annual risk loss and it can be reduced by the appropriate dynamic voltage support. The annual risk loss consists of state separating risk costs and transferring risk costs. The objective function of dynamic voltage support planning is to maximize the yearly average profit of the state without and with additional dynamic voltage support for the power system. The model is able to describe all kinds of voltage instability scenarios caused by REN interior faults or interface failures properly. The optimal schemes of dynamic voltage support planning of Guangdong receiving end power grids in 2008 and 2010 are given as instance based upon the proposed model, which shows that the comprehensive allocation schemes are of great security and economical efficiency. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1520 / 1527
页数:8
相关论文
共 27 条
[1]  
AZADANI EN, 2008, 12 INT MIDDL E POW S
[2]  
BAGHAEE HR, 2008, JOINT INT C POW SYST
[3]  
BAGHAEE HR, 2008, 11 INT C OPT EL EL E
[4]   Optimal location and setting of SVC and TCSC devices using non-dominated sorting particle swarm optimization [J].
Benabid, R. ;
Boudour, M. ;
Abido, M. A. .
ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (12) :1668-1677
[5]   A fast corrective load shedding control scheme to prevent AC/DC systems voltage collapse [J].
Cai, Guanglin ;
Zhang, Yongjun ;
Chen, Rouyi ;
Cai, Zexiang .
EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2009, 19 (06) :869-879
[6]  
*CHIN EL POW RES I, 2007, PSD POW TOOLS US MAN
[7]  
FARSANGI MM, 2007, IEEE T POWER SYSTEMS, V22, P336
[8]   Two-leg three-phase inverter control for STATCOM and SSSC applications [J].
Griffo, Antonio ;
Lauria, Davide .
IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (01) :361-370
[9]   STATCOM impact study on the integration of a large wind farm into a weak loop power system [J].
Han, Chong ;
Huang, Alex Q. ;
Baran, Mesut E. ;
Bhattacharya, Subliashish ;
Litzenberger, Wayne ;
Anderson, Loren ;
Johnson, Anders L. ;
Edris, Abdel-Aty .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2008, 23 (01) :226-233
[10]  
HU A, 2005, IEEE PES TRANSM DIST