摘要
Introduction: The need to access the right ventricle might preclude transvenous placement of a defibrillation lead at implantable cardioverter defibrillator (ICD) placement, especially in small children or children with complex congenital heart defects. We investigated a subcutaneous array lead in addition to an abdominally placed "active can" ICD device in two children to avoid a thoracotomy, Methods and Results: The first child (age 12 years, 138 cm, 41 kg) had transposition of the great arteries with a subsequent surgical intra-atrial correction by the Mustard technique. The second child (age 14 years, 161 cm, 54 kg) had a single atrium and a single ventricle, d-transposition of the aorta, and atresia of the main pulmonary artery with a surgical anastomosis between the aorta and the right pulmonary artery by the Cooley technique, The defibrillation threshold was 18 J and <20 J at initial implantation and at generator replacement in the first patient and 20 J in the second patient. During follow-up of 6 years and 1 month, respectively, no ICD-related complications occurred. Conclusion: In children in whom endocardial, right ventricular placement of a defibrillation lead is precluded, defibrillation is possible and safe between an abdominally placed "active can" ICD device and a subcutaneous array lead. This approach may avoid a thoracotomy in children with no possibility for transvenous ICD placement.
引用
收藏
页码:356 / 360
页数:5
相关论文
共 21 条
[1]   A SIMPLIFIED, SINGLE-LEAD UNIPOLAR TRANSVENOUS CARDIOVERSION-DEFIBRILLATION SYSTEM [J].
BARDY, GH ;
JOHNSON, G ;
POOLE, JE ;
DOLACK, GL ;
KUDENCHUK, PJ ;
KELSO, D ;
MITCHELL, R ;
MEHRA, R ;
HOFER, B .
CIRCULATION, 1993, 88 (02) :543-547
[2]   A PROSPECTIVE RANDOMIZED EVALUATION OF BIPHASIC VERSUS MONOPHASIC WAVEFORM PULSES ON DEFIBRILLATION EFFICACY IN HUMANS [J].
BARDY, GH ;
IVEY, TD ;
ALLEN, MD ;
JOHNSON, G ;
MEHRA, R ;
GREENE, HL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) :728-733
[3]   A PROSPECTIVE RANDOMIZED CROSS-OVER COMPARISON OF MONOPHASIC AND BIPHASIC DEFIBRILLATION USING NONTHORACOTOMY LEAD CONFIGURATIONS IN HUMANS [J].
BLOCK, M ;
HAMMEL, D ;
BOCKER, D ;
BORGGREFE, M ;
BUDDE, T ;
ISBRUCH, F ;
WIETHOLT, D ;
SCHELD, HH ;
BREITHARDT, G .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1994, 5 (07) :581-590
[4]   Potential benefit from implantable cardioverter-defibrillator therapy in patients with and without heart failure [J].
Böcker, D ;
Bänsch, D ;
Heinecke, A ;
Weber, M ;
Brunn, J ;
Hammel, D ;
Borggrefe, M ;
Breithardt, G ;
Block, P .
CIRCULATION, 1998, 98 (16) :1636-1643
[5]   Canadian implantable defibrillator study (CIDS) - A randomized trial of the implantable cardioverter defibrillator against amiodarone [J].
Connolly, SJ ;
Gent, M ;
Roberts, RS ;
Dorian, P ;
Roy, D ;
Sheldon, RS ;
Mitchell, LB ;
Green, MS ;
Klein, GJ ;
O'Brien, B .
CIRCULATION, 2000, 101 (11) :1297-1302
[6]   Use of a single coil transvenous electrode with an abdominally placed implantable cardioverter defibrillator in children [J].
Fischbach, PS ;
Law, IH ;
Dick, M ;
Leroy, S ;
Mosca, RS ;
Serwer, GA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (05) :884-887
[7]   ACC/AHA Guidelines for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Executive summary - A report of the American College of Cardiology American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation) [J].
Gregoratos, G ;
Cheitlin, MD ;
Conill, A ;
Epstein, AE ;
Fellows, C ;
Ferguson, TB ;
Freedman, RA ;
Hlatky, MA ;
Naccarelli, GV ;
Saksena, S ;
Schlant, RC ;
Silka, MJ .
CIRCULATION, 1998, 97 (13) :1325-1335
[8]   Five-year experience with implantable defibrillators in children [J].
Hamilton, RM ;
Dorian, P ;
Gow, RM ;
Williams, WG .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (07) :524-&
[9]   THE SUBCUTANEOUS ARRAY - A NEW LEAD ADJUNCT FOR THE TRANSVENOUS ICD TO LOWER DEFIBRILLATION THRESHOLDS [J].
HIGGINS, SL ;
ALEXANDER, DC ;
KUYPERS, CJ ;
BREWSTER, SA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (08) :1540-1548
[10]   PRELIMINARY EXPERIENCE WITH NONTHORACOTOMY IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS IN YOUNG-PATIENTS [J].
KRON, J ;
SILKA, MJ ;
OHM, OJ ;
BARDY, G ;
BENDITT, D ;
CHILSON, D ;
GILLIS, AM ;
MITCHELL, LB ;
GULAMHUSEIN, S ;
KUCK, K ;
SIEBELS, J ;
BREITHARDT, G ;
BLOCK, M ;
TOUBOUL, P ;
PRADEL, L ;
BRACHMANN, J ;
RUSKIN, J ;
HAFFAJEE, C .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (01) :26-30