A simple and rapid method for measuring dissolved oxygen in waters with gold microelectrode

被引:18
作者
Chen, You-Peng [1 ]
Liu, Shao-Yang [1 ]
Yu, Han-Qing [1 ]
机构
[1] Univ Sci & Technol China, Dept Chem, Hefei 230026, Peoples R China
基金
中国国家自然科学基金;
关键词
dissolved oxygen; first derivative linear sweep voltammetry; microelectrode; scan rate; surface area; water;
D O I
10.1016/j.aca.2007.07.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dissolved oxygen (DO) is an essential indicator in chemical, biological and biochemical processes and needs to be rapidly measured in many cases. In this work, a rapid, sensitive and simple electrochemical method, first derivative linear sweep voltammetry (FD-LSV), was established for the determination of DO. The peak height of FD-LSV was found to be influenced by scan rate and microelectrode surface area. An empirical formula was proposed to describe the relationship between the FD-LSV peak height and the influencing factors. Compared with other electrochemical methods for DO determination, the FD-LSV method needed lesser time and was more accurate. This method was successfully applied for the determination of the DO levels of various environmental water samples. (c) 2007 Elsevier BN. All rights reserved.
引用
收藏
页码:249 / 253
页数:5
相关论文
共 15 条
[1]  
[Anonymous], 1995, STANDARD METHODS EXA, V19th
[2]   Evaluation of modelled and measured patterns of dissolved oxygen in a freshwater lake as an indicator of the presence of biodegradable organic pollution [J].
Ansa-Asare, OD ;
Marr, IL ;
Cresser, MS .
WATER RESEARCH, 2000, 34 (04) :1079-1088
[3]   SOLUBILITY OF GASES IN LIQUIDS [J].
BATTINO, R ;
CLEVER, HL .
CHEMICAL REVIEWS, 1966, 66 (04) :395-+
[4]   A composite thin film optical sensor for dissolved oxygen in contaminated aqueous environments [J].
Gillanders, RN ;
Tedford, MC ;
Crilly, PJ ;
Bailey, RT .
ANALYTICA CHIMICA ACTA, 2005, 545 (02) :189-194
[5]   SEMIDIFFERENTIAL ELECTROANALYSIS [J].
GOTO, M ;
ISHII, D .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1975, 61 (03) :361-365
[6]   Measurement of the dissolved oxygen concentration in acrylate monomers with a novel photochemical method [J].
Gou, LJ ;
Coretsopoulos, CN ;
Scranton, AB .
JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 2004, 42 (05) :1285-1292
[7]   SEMI-INTEGRAL ELECTROANALYSIS - THEORY AND VERIFICATION [J].
GRENNESS, M ;
OLDHAM, KB .
ANALYTICAL CHEMISTRY, 1972, 44 (07) :1121-&
[8]   Monitoring and kinetic study of ammonia oxidation using dissolved oxygen electrode and NAD(P) H fluorometer [J].
Ju, LK ;
Nallagatla, PB .
WATER RESEARCH, 2003, 37 (01) :188-196
[9]   Electrodes based on nanodispersed titanium and tungsten oxides for a sensor of dissolved oxygen [J].
Kolbasov, G. Ya. ;
Vorobets, V. S. ;
Korduban, A. M. ;
Shpak, A. P. ;
Medvedskii, M. M. ;
Kolbasova, I. G. ;
Linyucheva, I. V. .
RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 2006, 79 (04) :596-601
[10]   Dissolved oxygen sensor based on cobalt tetrasulphonated phthalocyanine immobilized in poly-L-lysine film onto glassy carbon electrode [J].
Luz, RDS ;
Damos, FS ;
Tanaka, AA ;
Kubota, LT .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (02) :1019-1027