A method for calibration and validation subset partitioning

被引:987
作者
Galvao, RKH
Araujo, MCU
José, GE
Pontes, MJC
Silva, EC
Saldanha, TCB
机构
[1] Univ Fed Paraiba, Dept Quim, BR-58051970 Joao Pessoa, Paraiba, Brazil
[2] Inst Tecnol Aeronaut, Div Engn Eletron, Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
sample subset partitioning; PLS regression; Kennard-Stone algorithm; NIR spectrometry; diesel analysis;
D O I
10.1016/j.talanta.2005.03.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper proposes a new method to divide a pool of samples into calibration and validation subsets for multivariate modelling. The proposed method is of value for analytical applications involving complex matrices, in which the composition variability of real samples cannot be easily reproduced by optimized experimental designs. A stepwise procedure is employed to select samples according to their differences in both x (instrumental responses) and y (predicted parameter) spaces. The proposed technique is illustrated in a case study involving the prediction of three quality parameters (specific mass and distillation temperatures at which 10 and 90% of the sample has evaporated) of diesel by NIR spectrometry and PLS modelling. For comparison, PLS models are also constructed by full cross-validation, as well as by using the Kennard-Stone and random sampling methods for calibration and validation subset partitioning. The obtained models are compared in terms of prediction performance by employing an independent set of samples not used for calibration or validation. The results of F-tests at 95% confidence level reveal that the proposed technique may be an advantageous alternative to the other three strategies. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:736 / 740
页数:5
相关论文
共 14 条
  • [1] [Anonymous], 1998, Chemometrics: A Practical Guide
  • [2] Standardization of near-infrared spectrometric instruments
    Bouveresse, E
    Hartmann, C
    Massart, DL
    Last, IR
    Prebble, KA
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (06) : 982 - 990
  • [3] Resolution of mixtures of three nonsteroidal anti-inflammatory drugs by fluorescence using partial least squares multivariate calibration with previous wavelength selection by Kohonen artificial neural networks
    Capitán-Vallvey, LF
    Navas, N
    del Olmo, M
    Consonni, V
    Todeschini, R
    [J]. TALANTA, 2000, 52 (06) : 1069 - 1079
  • [4] A strategy for selecting calibration samples for multivariate modelling
    Dantas, HA
    Galvao, RKH
    Araújo, MCU
    da Silva, EC
    Saldanha, TCB
    José, GE
    Pasquini, C
    Raimundo, IM
    Rohwedder, JJR
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2004, 72 (01) : 83 - 91
  • [5] Representative subset selection
    Daszykowski, M
    Walczak, B
    Massart, DL
    [J]. ANALYTICA CHIMICA ACTA, 2002, 468 (01) : 91 - 103
  • [6] Generation and mid-IR measurement of a gas-phase to predict security parameters of aviation jet fuel
    Gómez-Carracedo, MP
    Andrade, JM
    Calviño, MA
    Prada, D
    Fernández, E
    Muniategui, S
    [J]. TALANTA, 2003, 60 (05) : 1051 - 1062
  • [7] The application of near-infrared spectroscopy for the quality control analysis of rocket propellant fuel pre-mixes
    Judge, MD
    [J]. TALANTA, 2004, 62 (04) : 675 - 679
  • [8] KANDUC KR, 2003, CHEMOM INTELL LAB SY, V65, P221
  • [9] COMPUTER AIDED DESIGN OF EXPERIMENTS
    KENNARD, RW
    STONE, LA
    [J]. TECHNOMETRICS, 1969, 11 (01) : 137 - &
  • [10] Mansfield CT, 1999, ANAL CHEM, V71, p81R