Large-volume injections in capillary gas chromatography using a separately, heated packed pre-column: Application to mercury speciation in natural water

被引:15
作者
Hanstrom, S
Briche, C
Emteborg, H
Baxter, DC
机构
关键词
large-volume injection; gas chromatography; microwave-induced plasma atomic emission spectrometry; methylmercury; kinetic studies; natural water;
D O I
10.1039/an9962101657
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Large-volume injection using a system consisting of packed column GC, serially connected to capillary GC, and coupled to a microwave-induced plasma atomic emission spectrometric (MIP-AES) detector is described, The greater sample, capacity of the packed column is exploited to allow large-volume injections to be accommodated, preliminary chromatographic separation of the solvent and mercury species on the packed pre-column permits;selective transfer of the analytes to a capillary GC system. There, the mercury species can be focused and further separated on the analytical column, minimizing the risks of extinguishing the plasma due to excess solvent reaching the MIP, and stationary phase or detector fouling, which accompany large-volume injections using alternative methods, Application to the determination of mercury species in natural waters following solid-phase extraction on a dithiocarbamate resin, elution into acidic thiourea, complexometric extraction into hexane and Grignard derivatization is used to illustrate the benefits and limitations of this approach, The relative limit of detection obtained for methylmercury is 8 pg l(-1) utilizing 50 mu l injection on to the packed pre-column, compared with 40 pg l(-1) for direct injection of 13 mu l into the capillary GC-MIP-AES system, This improved performance has enabled more detailed kinetic studies of the uptake of methylmercury from humic-rich natural waters on the dithiocarbamate resin to be undertaken, and shows that incipient and added analyte behave differently during enrichment, which may have implications for the use of spiking during method development.
引用
收藏
页码:1657 / 1663
页数:7
相关论文
共 29 条
[1]   SPECTRUM, MULTIELEMENT SELECTIVITY AND ELEMENTAL RESPONSE OF A LINEAR SULFUR EMITTER IN FLAME PHOTOMETRY [J].
AUE, WA ;
SUN, XY .
JOURNAL OF CHROMATOGRAPHY, 1993, 633 (1-2) :151-162
[3]   HUMIC MACROMOLECULES IN NATURAL-WATERS [J].
BOGGS, S ;
LIVERMORE, DG ;
SEITZ, MG .
JOURNAL OF MACROMOLECULAR SCIENCE-REVIEWS IN MACROMOLECULAR CHEMISTRY AND PHYSICS, 1985, C25 (04) :599-657
[4]   SIMPLIFIED SAMPLE PREPARATION FOR GC SPECIATION ANALYSIS OF ORGANOTIN IN MARINE BIOMATERIALS [J].
CEULEMANS, M ;
WITTE, C ;
LOBINSKI, R ;
ADAMS, FC .
APPLIED ORGANOMETALLIC CHEMISTRY, 1994, 8 (05) :451-461
[5]   SPECIATION ANALYSIS OF ORGANOTIN IN WATER AND SEDIMENTS BY GAS-CHROMATOGRAPHY WITH OPTICAL SPECTROMETRIC DETECTION AFTER EXTRACTION SEPARATION [J].
DIRKX, WMR ;
LOBINSKI, R ;
ADAMS, FC .
ANALYTICA CHIMICA ACTA, 1994, 286 (03) :309-318
[6]  
Donard O. F. X., 1989, ENV ANAL USING CHROM, P189
[7]   Gas chromatography coupled with atomic absorption spectrometry - A sensitive instrumentation for mercury speciation [J].
Emteborg, H ;
Sinemus, HW ;
Radziuk, B ;
Baxter, DC ;
Frech, W .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (08) :829-837
[8]   SPECIATION OF MERCURY IN NATURAL-WATERS BY CAPILLARY GAS-CHROMATOGRAPHY WITH A MICROWAVE-INDUCED PLASMA EMISSION DETECTOR FOLLOWING PRECONCENTRATION USING A DITHIOCARBAMATE RESIN MICROCOLUMN INSTALLED IN A CLOSED FLOW-INJECTION SYSTEM [J].
EMTEBORG, H ;
BAXTER, DC ;
FRECH, W .
ANALYST, 1993, 118 (08) :1007-1013
[9]   EVALUATION, MECHANISM AND APPLICATION OF SOLID-PHASE EXTRACTION USING A DITHIOCARBAMATE RESIN FOR THE SAMPLING AND DETERMINATION OF MERCURY SPECIES IN HUMIC-RICH NATURAL-WATERS [J].
EMTEBORG, H ;
BAXTER, DC ;
SHARP, M ;
FRECH, W .
ANALYST, 1995, 120 (01) :69-77
[10]   ON-COLUMN INJECTION OF LARGE SAMPLE VOLUMES USING THE RETENTION GAP TECHNIQUE IN CAPILLARY GAS-CHROMATOGRAPHY [J].
GROB, K ;
KARRER, G ;
RIEKKOLA, ML .
JOURNAL OF CHROMATOGRAPHY, 1985, 334 (02) :129-155