Purpose: The purpose of this work was to explore the reproducibility of fat-fraction measurements using Dixon quantitative chemical shift imaging (QCSI) in the lumbar spine (L3, L4, and L5) of healthy volunteers. Method: Sixteen healthy volunteers were examined at 1.5 T two times to obtain a repeated measurement in the same slice and a third time in three parallel slices. Single slice, two point Dixon SE (TR/TE 2,500/22.3) sequences were used, from which fat-fraction images were calculated. The fat-fraction results are presented as averages over regions of interest, which were derived from the contours of the vertebrae. Reproducibility measures related to repeated measurements on different days, slice position, and contour drawing were calculated. Results: The mean fat fraction was 0.37 (SD 0.08). The SD due to repeated measurement was small (sigma (R) = 0.013-0.032), almost all of which can be explained by slice-(re)-positioning errors. Conclusion: When used to evaluate the same person longitudinally in time, Dixon QCSI fat-fraction measurement has an excellent reproducibility. It is a powerful noninvasive tool in the evaluation of bone marrow composition.
引用
收藏
页码:691 / 697
页数:7
相关论文
共 30 条
[1]  
Akkerman E., 1995, P SOC MAGN RES EUR S, P649
[2]  
[Anonymous], 1997, PRACTICAL STAT MED R
[3]   Quantitative assessment of bone marrow hematopoiesis using parametric magnetic resonance imaging [J].
Ballon, D ;
Jakubowski, AA ;
Tulipano, PK ;
Graham, MC ;
Schneider, E ;
Aghazadeh, B ;
Chen, QS ;
Koutcher, JA .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (05) :789-800
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   MR-IMAGING OF FAT-CONTAINING TISSUES - VALUATION OF 2 QUANTITATIVE IMAGING TECHNIQUES IN COMPARISON WITH LOCALIZED PROTON SPECTROSCOPY [J].
BRIX, G ;
HEILAND, S ;
BELLEMANN, ME ;
KOCH, T ;
LORENZ, WJ .
MAGNETIC RESONANCE IMAGING, 1993, 11 (07) :977-991
[6]   H-1-SPECTROSCOPIC IMAGING USING A MODIFIED DIXON METHOD [J].
BRIX, G ;
SCHAD, LR ;
LORENZ, WJ .
MAGNETIC RESONANCE IMAGING, 1988, 6 (06) :617-622
[7]   QUANTITATIVE PROTON CHEMICAL-SHIFT IMAGING [J].
BUXTON, RB ;
WISMER, GL ;
BRADY, TJ ;
ROSEN, BR .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :881-900
[8]   ACTIVE BONE-MARROW DISTRIBUTION AS A FUNCTION OF AGE IN HUMANS [J].
CRISTY, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (03) :389-400
[9]   In-phase and out-of-phase MR imaging of bone marrow: Prediction of neoplasia based on the detection of coexistent fat and water [J].
Disler, DG ;
McCauley, TR ;
Ratner, LM ;
Kesack, CD ;
Cooper, JA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (05) :1439-1447
[10]   SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194