3 Tesla MR imaging provides improved contrast in first-pass myocardial perfusion imaging over a range of gadolinium doses

被引:54
作者
Araoz, PA
Glockner, JF
Mcgee, KP
Potter, DD
Valeti, VU
Stanley, DW
Christian, TF
机构
[1] Mayo Clin & Mayo Fdn, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Dept Surg, Div Cardiothorac Surg, Rochester, MN 55905 USA
[3] Mayo Clin & Mayo Fdn, Dept Internal Med, Div Cardiovasc Dis, Rochester, MN 55905 USA
[4] GE Co, Med Syst, Milwaukee, WI 53201 USA
关键词
perfusion; 3; Tesla; contrast;
D O I
10.1081/JCMR-200060622
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose. To compare myocardial enhancement during first-pass myocardial perfusion imaging at 3.0 Tesla (T) and 1.5T. Materials and Methods. First-pass myocardial perfusion imaging was performed on twelve normal subjects at 3T and 1.5T using an interleaved notched saturation recovery gradient echo pulse sequence. Subjects received either 0.10 mmol/kg for both scans (group 1), 0.075 mmok/kg for both scans (group 2), or 0.075 mmol/kg for the 3T scan and 0.10 mmol/kg for the 1.5T scan (group 3). Results. Contrast enhancement was significantly greater at 3T than at 1.5T for the 12 subjects whether enhancement was normalized to baseline signal intensity (2.58 +/- 0.76 vs. 1.52 +/- 0.37, p < 0.0001) or to noise (57.6 +/- 19.7 vs. 14.7 +/- 7.8, p < 0001). For each of the three groups, contrast enhancement was significantly greater at 3T versus 1.5T (p < 0.0001, p < 0.001, p < 0.008 when normalized to baseline signal; p < 0.0001 for all groups when normalized to noise). Conclusion. 3T improves contrast in first-pass myocardial perfusion imaging at either 0.10 mmol/kg or 0.075 mmol/kg.
引用
收藏
页码:559 / 564
页数:6
相关论文
共 17 条
[11]  
Noeske R, 2000, MAGN RESON MED, V44, P978, DOI 10.1002/1522-2594(200012)44:6<978::AID-MRM22>3.0.CO
[12]  
2-9
[13]   Field strength and dose dependence of contrast enhancement by gadolinium-based MR contrast agents [J].
Rinck, PA ;
Muller, RN .
EUROPEAN RADIOLOGY, 1999, 9 (05) :998-1004
[14]   Magnetic resonance perfusion imaging in patients with coronary artery disease: a qualitative approach [J].
Sensky, PR ;
Samani, NJ ;
Reek, C ;
Cherryman, GR .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2002, 18 (05) :373-383
[15]   First-pass myocardial perfusion MR imaging with interleaved notched saturation: Feasibility study [J].
Slavin, GS ;
Wolff, SD ;
Gupta, SN ;
Foo, TKF .
RADIOLOGY, 2001, 219 (01) :258-263
[16]   The intrinsic signal-to-noise ratio in human cardiac imaging at 1.5, 3, and 4 T [J].
Wen, H ;
Denison, TJ ;
Singerman, RW ;
Balaban, RS .
JOURNAL OF MAGNETIC RESONANCE, 1997, 125 (01) :65-71
[17]  
Wilke NM, 1999, JMRI-J MAGN RESON IM, V10, P676