Petroleomics: The next grand challenge for chemical analysis

被引:663
作者
Marshall, AG [1 ]
Rodgers, RP
机构
[1] Florida State Univ, Dept Chem & Biochem, Tallahassee, FL 32306 USA
[2] Florida State Univ, Ion Cyclotron Resonance Program, Natl High Magnet Field Lab, Tallahassee, FL 32310 USA
关键词
D O I
10.1021/ar020177t
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry has recently revealed that petroleum crude oil contains heteroatom-containing (N,O,S) organic components having more than 20 000 distinct elemental compositions (CcHhNnOoSs). It is therefore now possible to contemplate the ultimate characterization of all of the chemical constituents of petroleum, along with their interactions and reactivity, a concept we denote as "petroleomics". Such knowledge has already proved capable of distinguishing petroleum and its distillates according to their geochemical origin and maturity, distillation cut, extraction method, catalytic processing, etc. The key features that have opened up this new field have been (a) ultrahigh-resolution FT-ICR mass analysis, specifically, the capability to resolve species differing in elemental composition by C-3 vs SH4 (i.e., 0.0034 Da); (b) higher magnetic field to cover the whole mass range at once; (c) dynamic range extension by external mass filtering; and (d) plots of Kendrick mass defect vs nominal Kendrick mass as a means for sorting different compound "classes" (i.e., numbers of N, O, and S atoms), "types" (rings plus double bonds), and alkylation ((-CH2)(n)) distributions, thereby extending to >900 Da the upper limit for unique assignment of elemental composition based on accurate mass measurement. The same methods are also being applied successfully to analysis of humic and fulvic acids, coals, and other complex natural mixtures, often without prior or on-line chromatographic separation.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 59 条
[1]  
Altgelt K. H., 1994, COMPOSITION ANAL HEA
[2]   The 1995 update to the atomic mass evaluation [J].
Audi, G ;
Wapstra, AH .
NUCLEAR PHYSICS A, 1995, 595 (04) :409-480
[3]  
Beynon J., 1963, MASS ABUNDANCE TABLE
[4]   GEONIUM THEORY - PHYSICS OF A SINGLE ELECTRON OR ION IN A PENNING TRAP [J].
BROWN, LS ;
GABRIELSE, G .
REVIEWS OF MODERN PHYSICS, 1986, 58 (01) :233-311
[5]  
BUENROSTROGONZA.E, 2001, ENERG FUEL, P972
[6]   Draft data leave geneticists with a mountain still to climb [J].
Butler, D ;
Smaglik, P .
NATURE, 2000, 405 (6790) :984-985
[7]   STORED WAVE-FORM SIMULTANEOUS MASS-SELECTIVE EJECTION EXCITATION FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CHEN, L ;
MARSHALL, AG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1987, 79 (01) :115-125
[8]  
CHEN L, 1986, CHEMOMETRICS INTELLI, V1, P51
[9]   FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SPECTROSCOPY [J].
COMISAROW, MB ;
MARSHALL, AG .
CHEMICAL PHYSICS LETTERS, 1974, 25 (02) :282-283
[10]   High-resolution Fourier transform ion cyclotron resonance mass spectrometry of humic and fulvic acids by laser desorption/ionization and electrospray ionization [J].
Fievre, A ;
Solouki, T ;
Marshall, AG ;
Cooper, WT .
ENERGY & FUELS, 1997, 11 (03) :554-560