Role of Echocardiography in Percutaneous Aortic Valve Implantation

被引:183
作者
Moss, Robert R. [1 ,3 ]
Ivens, Emma [1 ,3 ]
Pasupati, Sanjeevan [1 ,3 ]
Humphries, Karin [1 ,2 ,3 ]
Thompson, Christopher R. [1 ,3 ]
Munt, Brad [1 ,3 ]
Sinhal, Ajay [1 ,3 ]
Webb, John G. [1 ,3 ]
机构
[1] St Pauls Hosp, Div Cardiol, Vancouver, BC V6Z 1Y6, Canada
[2] St Pauls Hosp, Ctr Hlth Evaluat & Outcome Sci, Vancouver, BC V6Z 1Y6, Canada
[3] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
关键词
D O I
10.1016/j.jcmg.2007.09.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study was designed to investigate the usefulness and limitations of echocardiography in optimizing the outcome of percutaneous aortic valve implantation. BACKGROUND Percutaneous aortic valve implantation is an emerging technique that has the potential to revolutionize the treatment of aortic valve disease. To date, however, the technique has been limited by technical constraints. Precise positioning of the valve is essential to minimize the potential for paravalvular regurgitation or device migration. Initial experience with device placement utilized fluoroscopic guidance only. METHODS Candidates for percutaneous aortic valve implantation were evaluated with transthoracic echocardiography (TTE) to assess aortic annular dimension and aortic valve hemodynamics. Fifty consecutive patients were deemed suitable for percutaneous aortic valve implantation. Seventy-four percent (37 of 50) of patients underwent transesophageal echocardiography (TEE) during the procedure. RESULTS Eighty-six percent (43 of 50) of patients had successful implantation, of which 77% (33 of 43) had TEE. Transthoracic echocardiography was used to determine annular dimension and was useful in guiding correct device sizing. Transesophageal echocardiography was able to successfully guide device implantation in 97% (33 of 34) of patients in whom the native valve was crossed with the percutaneous heart valve. Transesophageal echocardiography was used for the early detection of paravalvular aortic regurgitation (AR) and complemented fluoroscopy in the detection of complications. Additional balloon dilatation of the percutaneous heart valve was performed in 12 patients because of significant paravalvular AR, with 7 showing improvement in AR grade. After the procedure, early outcomes were evaluated using TTE. All patients in whom the device was successfully placed (43 of 50) had improvement in their aortic stenosis. Paravalvular AR, although present in many patients, is usually mild and has not emerged as a significant problem. CONCLUSIONS Echocardiography has an important role in case selection, in guiding device placement, and in detecting complications of percutaneous aortic valve implantation. (J Am Coll Cardiol Img 2008;1:15-24) (C) 2008 by the American College of Cardiology Foundation
引用
收藏
页码:15 / 24
页数:10
相关论文
共 9 条
  • [1] Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description
    Cribier, A
    Eltchaninoff, H
    Bash, A
    Borenstein, N
    Tron, C
    Bauer, F
    Derumeaux, G
    Anselme, F
    Laborde, F
    Leon, MB
    [J]. CIRCULATION, 2002, 106 (24) : 3006 - 3008
  • [2] Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiography
    Ionescu, A
    Fraser, AG
    Butchart, EG
    [J]. HEART, 2003, 89 (11) : 1316 - 1321
  • [3] DOPPLER COLOR FLOW MAPPING IN THE EVALUATION OF PROSTHETIC MITRAL AND AORTIC-VALVE FUNCTION
    KAPUR, KK
    FAN, P
    NANDA, NC
    YOGANATHAN, AP
    GOYAL, RG
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (07) : 1561 - 1571
  • [4] BALLOON AORTIC VALVULOPLASTY IN ADULTS - FAILURE OF PROCEDURE TO IMPROVE LONG-TERM SURVIVAL
    LIEBERMAN, EB
    BASHORE, TM
    HERMILLER, JB
    WILSON, JS
    PIEPER, KS
    KEELER, GP
    PIERCE, CH
    KISSLO, KB
    HARRISON, JK
    DAVIDSON, CJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (06) : 1522 - 1528
  • [5] 3-YEAR OUTCOME AFTER BALLOON AORTIC VALVULOPLASTY - INSIGHTS INTO PROGNOSIS OF VALVULAR AORTIC-STENOSIS
    OTTO, CM
    MICKEL, MC
    KENNEDY, JW
    ALDERMAN, EL
    BASHORE, TM
    BLOCK, PC
    BRINKER, JA
    DIVER, D
    FERGUSON, J
    HOLMES, DR
    LAMBREW, CT
    MCKAY, CR
    PALACIOS, IF
    POWERS, ER
    RAHIMTOOLA, SH
    WEINER, BH
    DAVIS, KB
    [J]. CIRCULATION, 1994, 89 (02) : 642 - 650
  • [6] Natural history of early aortic paraprosthetic regurgitation: A five-year follow-up
    Rallidis, LS
    Moyssakis, IE
    Ikonomidis, I
    Nihoyannopoulos, P
    [J]. AMERICAN HEART JOURNAL, 1999, 138 (02) : 351 - 357
  • [7] Percutaneous aortic valve implantation retrograde from the femoral artery
    Webb, JG
    Chandavimol, M
    Thompson, CR
    Ricci, DR
    Carere, RG
    Munt, BI
    Buller, CE
    Pasupati, S
    Lichtenstein, S
    [J]. CIRCULATION, 2006, 113 (06) : 842 - 850
  • [8] Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis
    Webb, John G.
    Pasupati, Sanjeevan
    Humphries, Karin
    Thompson, Christopher
    Altwegg, Lukas
    Moss, Robert
    Sinhal, Ajay
    Carere, Ronald G.
    Munt, Brad
    Ricci, Donald
    Ye, Jian
    Cheung, Anson
    Lichtenstein, Sam V.
    [J]. CIRCULATION, 2007, 116 (07) : 755 - 763
  • [9] Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography
    Zoghbi, WA
    Enriquez-Sarano, M
    Foster, E
    Grayburn, PA
    Kraft, CD
    Levine, RA
    Nihoyannopoulos, P
    Otto, CM
    Quinones, MA
    Rakowski, H
    Stewart, WJ
    Waggoner, A
    Weissman, NJ
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2003, 16 (07) : 777 - 802