Wind-induced pressure at external surfaces of a high-rise residential building in Hong Kong

被引:34
作者
Burnett, J
Bojic, M
Yik, F
机构
[1] Univ Kragujevac, Fac Mech Engn, YU-34000 Kragujevac, Serbia
[2] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
CFD; wind; cross-ventilation;
D O I
10.1016/j.buildenv.2004.08.019
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The paper presents results of computational fluid dynamics simulations of pressure at external surfaces of a typical high-rise residential building in Hong Kong in order to comment on wind-driven ventilation inside the flats. The simulations used k - epsilon turbulence model, and two and three-dimensional model of the building. The results reveal that an optimal building orientation relative to the wind can be found; the windward flats possess the best cross-ventilation potential; in the investigated flats, location of windows and rooms is not adequate to maximize cross-ventilation potential and minimize spread of odour. The new building plan provides better cross-ventilation. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:765 / 777
页数:13
相关论文
共 14 条
[1]  
*ARCH SERV DEP, 2002, ENV HLTH SAF REP 200
[2]  
ASHRAE, 1997, ASHRAE Handbook SI (Fundamentals)
[3]   Computational study of natural ventilation [J].
Ayad, SS .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1999, 82 :49-68
[4]  
*BUILD DEP, 2001, LANDS DEP PLANN DEP
[5]  
*BUILD DEP, 1995, COD PRACT MEANS ACC
[6]  
*BUILD DEP HONG KO, 2001 BUILD DEP ENV
[7]  
*CTR ENV TECHN, 1999, ENV ASS NEW RES BUIL
[8]  
*DEP HLTH, 2003, TREAS OUR CIT KEEP H, V23
[9]  
*FLUENT INC, 1999, FLUENT VERS 4 23 US
[10]   Evaluation of pedestrian winds in urban area by numerical approach [J].
He, JM ;
Song, CCS .