High-repetition-rate grazing-incidence pumped x-ray laser operating at 18.9 nm

被引:189
作者
Keenan, R [1 ]
Dunn, J
Patel, PK
Price, DF
Smith, RF
Shlyaptsev, VN
机构
[1] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA
[2] Univ Calif Davis, Dept Appl Sci, Livermore, CA 94551 USA
关键词
D O I
10.1103/PhysRevLett.94.103901
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We have demonstrated a 10 Hz Ni-like Mo x-ray laser operating at 18.9 nm with 150 mJ total pump energy by employing a novel pumping scheme. The grazing-incidence scheme is described, where a picosecond pulse is incident at a grazing angle to a Mo plasma column produced by a slab target irradiated by a 200 ps laser pulse. This scheme uses refraction of the short pulse at a predetermined electron density to increase absorption to pump a specific gain region. The higher coupling efficiency inherent to this scheme allows a reduction in the pump energy where 70 mJ long pulse energy and 80 mJ short pulse energy are sufficient to produce lasing at a 10 Hz repetition rate. Under these conditions and by optimizing the delay between the pulses, we achieve strong amplification and close to saturation for 4 mm long targets.
引用
收藏
页数:4
相关论文
共 20 条
[1]  
BASOV NG, 1989, J SOV LASER RES, V10, P1
[2]   Gain saturation regime for laser-driven tabletop, transient Ni-like ion x-ray lasers [J].
Dunn, J ;
Li, Y ;
Osterheld, AL ;
Nilsen, J ;
Hunter, JR ;
Shlyaptsev, VN .
PHYSICAL REVIEW LETTERS, 2000, 84 (21) :4834-4837
[3]  
GINZBURG VL, 1964, PROPAGATION ELECTROM
[4]   Saturated x-ray lasers at 196 and 73 Å pumped by a picosecond traveling-wave excitation -: art. no. 053810 [J].
King, RE ;
Pert, GJ ;
McCabe, SP ;
Simms, PA ;
MacPhee, AG ;
Lewis, CLS ;
Keenan, R ;
O'Rourke, RMN ;
Tallents, GJ ;
Pestehe, SJ ;
Strati, F ;
Neely, D ;
Allott, R .
PHYSICAL REVIEW A, 2001, 64 (05) :12
[5]   DEMONSTRATION OF A 1O-HZ FEMTOSECOND PULSE-DRIVEN XUV LASER AT 41.8-NM IN XE-IX [J].
LEMOFF, BE ;
YIN, GY ;
GORDON, CL ;
BARTY, CPJ ;
HARRIS, SE .
PHYSICAL REVIEW LETTERS, 1995, 74 (09) :1574-1577
[6]  
LI R, 2001, J PHYS IV, P11
[7]   Generation of millijoule-level soft-x-ray laser pulses at a 4-Hz repetition rate in a highly saturated tabletop capillary discharge amplifier [J].
Macchietto, CD ;
Benware, BR ;
Rocca, JJ .
OPTICS LETTERS, 1999, 24 (16) :1115-1117
[8]   DEMONSTRATION OF A SOFT-X-RAY AMPLIFIER [J].
MATTHEWS, DL ;
HAGELSTEIN, PL ;
ROSEN, MD ;
ECKART, MJ ;
CEGLIO, NM ;
HAZI, AU ;
MEDECKI, H ;
MACGOWAN, BJ ;
TREBES, JE ;
WHITTEN, BL ;
CAMPBELL, EM ;
HATCHER, CW ;
HAWRYLUK, AM ;
KAUFFMAN, RL ;
PLEASANCE, LD ;
RAMBACH, G ;
SCOFIELD, JH ;
STONE, G ;
WEAVER, TA .
PHYSICAL REVIEW LETTERS, 1985, 54 (02) :110-113
[9]   Short pulse x-ray laser 32.6 nm based on transient gain in Ne-like titanium [J].
Nickles, PV ;
Shlyaptsev, VN ;
Kalachnikov, M ;
Schnurer, M ;
Will, I ;
Sandner, W .
PHYSICAL REVIEW LETTERS, 1997, 78 (14) :2748-2751
[10]   PREPULSE TECHNIQUE FOR PRODUCING LOW-Z NE-LIKE X-RAY LASERS [J].
NILSEN, J ;
MACGOWAN, BJ ;
DASILVA, LB ;
MORENO, JC .
PHYSICAL REVIEW A, 1993, 48 (06) :4682-4685