Preparation of the first European working standard for phenylalanine determination in dried blood spots

被引:14
作者
Dhondt, JL
Loeber, J
Elvers, LH
Paux, E
机构
[1] Fac Med, Ctr Reg Depistage Neonatal, F-59000 Lille, France
[2] RIVM, Diagnost Lab Infect Dis & Perinatal Screening, Bilthoven, Netherlands
关键词
phenylalanine; newborn screening; blood spot; calibrators; standardisation;
D O I
10.1136/jms.5.2.63
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 [公共卫生与预防医学]; 120402 [社会医学与卫生事业管理];
摘要
Objective-To develop a standard preparation for measurement of phenylalanine in blood spots in phenylketonuria against which manufacturers of kits for phenylalanine determination could calibrate their own blood spot calibrators. Methods-As most of the variation of phenylalanine concentration in dried blood spots is due to the way the blood spot calibrators are prepared, a minimum set of prerequisites for the preparation of blood spot calibrators was established by a group of scientific experts and manufacturers. A ((European working standard for phenylalanine in blood spots)) (EWS-Phe-01) was prepared and distributed to manufacturers taking part in this project. Results-The control of the homogeneity, linearity, and stability of the EWS-Phe-01 batch gave results within expected ranges. The preliminary results of the recalibration of calibrators for phenylalanine against EWS-Phe-01 by the participating manufacturers were promising; the differences between measurements were much decreased. Conclusion-Manufacturers have agreed to use EWS-Phe-01, and since November 1996 EWS-Phe calibrators have been routinely available from these companies. This pilot study may act as a model for minimising discrepancies found in other screening tests.
引用
收藏
页码:63 / 66
页数:4
相关论文
共 9 条
[1]
ULTRAVIOLET ABSORPTION SPECTRA OF PROTEINS AND AMINO ACIDS [J].
BEAVEN, GH ;
HOLIDAY, ER .
ADVANCES IN PROTEIN CHEMISTRY, 1952, 7 :319-386
[2]
BREMER HJ, 1981, DISTURBANCES AMINO A
[3]
*CDC, 1994, INF SCREEN QUAL ASS, P11
[4]
Need for a standardized procedure in the preparation of phenylalanine calibrators [J].
Dhondt, JL ;
Paux, E ;
Farriaux, JP .
EARLY HUMAN DEVELOPMENT, 1996, 45 (03) :277-285
[5]
The need for standardized bloodspot TSH-calibrators in congenital hypothyroidism screening [J].
Elvers, LH ;
Loeber, JG .
EARLY HUMAN DEVELOPMENT, 1996, 45 (1-2) :179-190
[6]
ELVERS LH, 1996, 199003047 RIVM
[7]
GUTHRIE R, 1963, PEDIATRICS, V32, P338
[8]
*NCCLS, 1983, NCCLS PUBL
[9]
INACCURACY IN PHENYLALANINE MEASUREMENTS - A PROBLEM TOWARDS ACCEPTANCE OF COMMON SCREENING APPROACHES [J].
TUUMINEN, T .
SCREENING, 1995, 4 (01) :47-51