Cozart® RapiScan oral fluid drug testing system:: An evaluation of sensitivity, specificity, and efficiency for cocaine detection compared with ELISA and GC-MS following controlled cocaine administration

被引:22
作者
Kolbrich, EA
Kim, I
Barnes, AJ
Moolchan, ET
Wilson, L
Cooper, GA
Reid, C
Baldwin, D
Hand, CW
Huestis, MA
机构
[1] NIDA, Chem & Drug Metab Sect, Intramural Res Program, NIH, Baltimore, MD 21224 USA
[2] Cozart Biosci Ltd, Abingdon OX14 4RU, Oxon, England
基金
美国国家卫生研究院;
关键词
D O I
10.1093/jat/27.7.407
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Oral fluid has become a widely accepted alternative matrix for drugs of abuse detection. Immunoassays have been developed for on-site testing of cocaine and metabolites in oral fluid. The performance of the Cozart RapiScan Oral Fluid Drug Testing System (CRS) was evaluated in comparison with Cozart Microplate Enzyme Immunoassay Cocaine Oral Fluid Kit (COC ELISA) and gas chromatography-mass spectrometry (GC-MS) at several screening and confirmation cutoffs, including those proposed by SAMHSA and those currently in use in the U.K. Oral fluid samples (n = 1271) were collected prior to and following controlled clinical cocaine administration. CRS provides a qualitative screen at a preset cutoff of 30 pg/L. Sensitivity, specificity, and efficiency for CRS (30 pg/L) as compared with COC ELISA with a cutoff of 30 pg/L were 92.1%, 91.8%, and 92.0%. The comparison of CRS (30 pg/L) with the 8-mg/L proposed SAMHSA confirmation cutoffs for cocaine and/or benzoylecgonine exhibited a sensitivity of 82.7%, a specificity of 94.5%, and an efficiency of 87.6%. For this study, an alternative CRS cutoff of 20 μg/L was also evaluated. Performance characteristics of CRS (20 μg/L) at the proposed SAMHSA confirmation cutoffs were 89.9%, 89.7%, and 89.8%, respectively. At cutoffs in use in the U.K., 30-pg/L CRS screen and 15-μg/L GC-MS cutoffs for cocaine, benzoylecgonine, and/or ecgonine methyl ester sensitivity, specificity, and efficiency were 89.4%, 92.2%, and 90.7%, respectively. Cozart RapiScan had performance similar to the COC ELISA assay for the detection of cocaine exposure and suitable sensitivity and specificity at the proposed SAMHSA cutoffs.
引用
收藏
页码:407 / 411
页数:5
相关论文
共 23 条
[1]   THE URINARY-EXCRETION OF COCAINE AND METABOLITES IN HUMANS - A KINETIC-ANALYSIS OF PUBLISHED DATA [J].
AMBRE, J .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1985, 9 (06) :241-245
[2]   Comparison of point-of-collection screening of drugs of abuse in oral fluid with a laboratory-based urine screen [J].
Barrett, C ;
Good, C ;
Moore, C .
FORENSIC SCIENCE INTERNATIONAL, 2001, 122 (2-3) :163-166
[3]   KINETICS OF COCAINE DISTRIBUTION, ELIMINATION, AND CHRONOTROPIC EFFECTS [J].
CHOW, MJ ;
AMBRE, JJ ;
RUO, TI ;
ATKINSON, AJ ;
BOWSHER, DJ ;
FISCHMAN, MW .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1985, 38 (03) :318-324
[4]   CORRELATION OF SALIVA COCAINE LEVELS WITH PLASMA-LEVELS AND WITH PHARMACOLOGIC EFFECTS AFTER INTRAVENOUS COCAINE ADMINISTRATION IN HUMAN-SUBJECTS [J].
CONE, EJ ;
KUMOR, K ;
THOMPSON, LK ;
SHERER, M .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1988, 12 (04) :200-206
[5]  
*COZ BIOSC LTD, COZ MICR EIA COC OR
[6]   Cozart Rapiscan System: our experience with saliva tests [J].
De Giovanni, N ;
Fucci, N ;
Chiarotti, M ;
Scarlata, S .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (01) :1-6
[7]  
George S, 2002, CLIN CHEM, V48, P1639
[8]   A comparison between on-site immunoassay drug-testing devices and laboratory results [J].
Grönholm, M ;
Lillsunde, P .
FORENSIC SCIENCE INTERNATIONAL, 2001, 121 (1-2) :37-46
[9]   Sweat testing for cocaine, codeine and metabolites by gas chromatography - mass spectrometry [J].
Huestis, MA ;
Oyler, JM ;
Cone, EJ ;
Wstadik, AT ;
Schoendorfer, D ;
Joseph, RE .
JOURNAL OF CHROMATOGRAPHY B, 1999, 733 (1-2) :247-264
[10]   KINETICS OF COCAINE IN HUMANS AFTER INTRAVENOUS AND INTRANASAL ADMINISTRATION [J].
JAVAID, JI ;
MUSA, MN ;
FISCHMAN, M ;
SCHUSTER, CR ;
DAVIS, JM .
BIOPHARMACEUTICS & DRUG DISPOSITION, 1983, 4 (01) :9-18