Gas chromatography-mass spectrometry confirmation of Cozart RapiScan saliva methadone and opiates tests

被引:15
作者
Moore, L
Wicks, J
Spiehler, V
Holgate, R
机构
[1] Spiehler & Associates, Newport Beach, CA 92663 USA
[2] Cozart Biosci Ltd, Abingdon, Oxon, England
[3] Tricho Tech, Cardiff, S Glam, Wales
[4] Ferry Cross Subst Misuse Serv, Norwich, Norfolk, England
关键词
D O I
10.1093/jat/25.7.520
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The object of this study was to determine the sensitivity and specificity of the Cozart RapiScan onsite saliva test for methadone and opiates versus laboratory-based enzyme immunoassay (EIA) and gas chromatography-mass spectrometry (GC-MS) confirmation. Fifty saliva specimens were obtained from 28 volunteers among persons entering a substance abuse clinic. Specimens were tested onsite using the Cozart RapiScan Saliva test and Cozart RapiScan Reader. Specimens were retested by Cozart Microplate EIA assays on receipt at the laboratory and then frozen for later confirmation by GC-MS. For GC-MS, deuterated internal standards were added to specimen aliquots which were extracted using solid-phase columns at pH 6 and eluted with dichloromethane/isopropanol/ammonia (80:19:2). The dry residues were derivatized with PFOH and PFPA and dried, and the reconstituted extract was injected and quantitated by GC-MS. The Cozart RapiScan Methadone Saliva Assay was found to have a sensitivity and specificity of 100%±12% versus GC-MS (2-ng/ml cutoff) and a sensitivity of 100%±11% and a specificity of 95%±2.4% versus the Microplate EIA for methadone (30-ng/mL cutoff). The Cozart RapiScan Saliva Opiate test bad a sensitivity of 100%±12% and a specificity of 92%±3.2% versus GC-MS (2-ng/mL cutoff) and a sensitivity of 96%±2.2% and specificity of 95%±2.4% versus the Microplate EIA for opiates (30-ng/mL cutoff).
引用
收藏
页码:520 / 524
页数:5
相关论文
共 10 条
[1]   Saliva/plasma ratio of methadone and EDDP [J].
Bermejo, AM ;
Lucas, ACS ;
Tabernero, MJ .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2000, 24 (01) :70-72
[2]  
CONE EJ, 1990, J ANAL TOXICOL, V14, P1
[3]   SALIVA TESTING FOR DRUGS OF ABUSE [J].
CONE, EJ .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1993, 694 :91-127
[4]  
DVORCHIK BH, 1976, CLIN CHEM, V22, P868
[5]   A REVIEW OF THE USE OF SALIVA IN THE FORENSIC DETECTION OF DRUGS AND OTHER CHEMICALS [J].
IDOWU, OR ;
CADDY, B .
JOURNAL OF THE FORENSIC SCIENCE SOCIETY, 1982, 22 (02) :123-135
[6]  
Jehanli A, 2001, J FORENSIC SCI, V46, P1214
[7]   COMPARISON OF HEROIN AND COCAINE CONCENTRATIONS IN SALIVA WITH CONCENTRATIONS IN BLOOD AND PLASMA [J].
JENKINS, AJ ;
OYLER, JM ;
CONE, EJ .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1995, 19 (06) :359-374
[8]   Solid-phase microextraction in the determination of methadone in human saliva by gas chromatography-mass spectrometry [J].
Lucas, ACD ;
Bermejo, A ;
Fernández, P ;
Tabernero, MJ .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2000, 24 (02) :93-96
[9]  
SPIEHLER VR, 2001, P 2000 TIAFT M HELS
[10]  
WOLFF K, 1991, CLIN CHEM, V37, P1297