Transient elastic support for vein grafts using a constricting microfibrillar polymer wrap

被引:46
作者
El-Kurdi, Mohammed S. [1 ,2 ,5 ]
Hong, Yi [1 ,2 ]
Stankus, John J. [1 ,2 ,4 ]
Soletti, Lorenzo [1 ,2 ,3 ,5 ]
Wagner, William R. [1 ,2 ,3 ,4 ,5 ]
Vorp, David A. [1 ,2 ,3 ,5 ]
机构
[1] Univ Pittsburgh, Div Vasc Surg, McGowan Inst Regenerat Med, Pittsburgh, PA 15219 USA
[2] Univ Pittsburgh, Dept Surg, Pittsburgh, PA 15219 USA
[3] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15219 USA
[4] Univ Pittsburgh, Dept Chem Engn, Pittsburgh, PA 15219 USA
[5] Univ Pittsburgh, Ctr Vasc Remodeling & Regenerat, Pittsburgh, PA 15219 USA
关键词
electrospinning; vein graft; intimal hyperplasia; vein wrap;
D O I
10.1016/j.biomaterials.2008.04.009
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Arterial vein grafts (AVGs) often fail due to intimal hyperplasia, thrombosis, or accelerated atherosclerosis. Various approaches have been proposed to address AVG failure, including delivery of temporary mechanical support, many of which could be facilitated by perivascular placement of a biodegradable polymer wrap. The purpose of this work was to demonstrate that a polymer wrap can be applied to vein segments without compromising viability/function, and to demonstrate one potential application, i.e., gradually imposing the mid-wall circumferential wall stress (CWS) in wrapped veins exposed to arterial levels of pressure. Poly(ester urethane)urea, collagen, and elastin were combined in solution, and then electrospun onto freshly-excised porcine internal jugular vein segments. Tissue viability was assessed via Live/Dead (TM) staining for necrosis, and vasomotor challenge with epinephrine and sodium nitroprusside for functionality, Wrapped vein segments were also perfused for 24 h within an ex vivo vascular perfusion system under arterial conditions (pressure = 120/80 mmHg; flow 100 mL/min), and CWS was calculated every hour. Our results showed that the electrospinning process had no deleterious effects on tissue viability, and that the mid-wall CWS vs. time profile could be dictated through the composition and degradation of the electrospun wrap. This may have important clinical applications by enabling the engineering of an improved AVG. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3213 / 3220
页数:8
相关论文
共 33 条
[1]
AHA, 2006, HEART DIS STROK STAT
[2]
BUNT TJ, 1983, SURGERY, V93, P733
[3]
PATHOPHYSIOLOGY OF VEIN GRAFT FAILURE - A REVIEW [J].
DAVIES, MG ;
HAGEN, PO .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1995, 9 (01) :7-18
[4]
DOBRIN PB, 1989, SURGERY, V105, P393
[5]
Peripheral bypass surgery and amputation - Northern Illinois demographics, 1993 to 1997 [J].
Feinglass, J ;
Kaushik, S ;
Handel, D ;
Kosifas, A ;
Martin, GJ ;
Pearce, WH .
ARCHIVES OF SURGERY, 2000, 135 (01) :75-80
[6]
In vivo evaluation of a porous, elastic, biodegradable patch for reconstructive cardiac procedures [J].
Fujimoto, Kazuro L. ;
Guan, Jianjun ;
Oshima, Hideki ;
Sakai, Tetsuro ;
Wagner, William R. .
ANNALS OF THORACIC SURGERY, 2007, 83 (02) :648-654
[7]
Gelabert HA, 2007, J VASC SURG, V45, P1037
[8]
Synthesis, characterization, and cytocompatibility of efastomeric, biodegradable poly(ester-urethane)ureas based on poly(caprolactone) and putrescine [J].
Guan, JJ ;
Sacks, MS ;
Beckman, EJ ;
Wagner, WR .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 61 (03) :493-503
[9]
Shear stress and pressure modulate saphenous vein remodeling ex vivo [J].
Gusic, RJ ;
Myung, R ;
Petko, M ;
Gaynor, JW ;
Gooch, KJ .
JOURNAL OF BIOMECHANICS, 2005, 38 (09) :1760-1769
[10]
EXPERIMENTAL APPROACHES ON MEASURING THE MECHANICAL-PROPERTIES AND CONSTITUTIVE LAWS OF ARTERIAL-WALLS [J].
HAYASHI, K .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :481-488