Development and evaluation of three real-time immuno-PCR assemblages for quantification of PSA

被引:77
作者
Lind, K
Kubista, M
机构
[1] Chalmers Univ Technol, Dept Chem & Biosci, S-40530 Gothenburg, Sweden
[2] TATAA Bioctr, S-40530 Gothenburg, Sweden
关键词
real-time immuno-PCR; real-time PCR; PSA;
D O I
10.1016/j.jim.2005.06.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Real-time PCR is a very sensitive technique to measure DNA concentrations. In real-time immuno-PCR, it is used as the detection system for quantification of proteins. Many ways to perform and assemble real-time immuno-PCR are possible. We have tested three different approaches for the detection of prostate specific antigen (PSA) and compared them with each other and with ELISA. We also demonstrate the applicability of real-time immuno-PCR to classify clinical PSA samples. Assemblage III is performed stepwise attaching the capture antibody to the vessel surface by adsorption and having the DNA-label linked to the detection antibody through biotin and streptavidin. In assemblage II, capture antibody is also adsorbed to the vessel surface but the detection antibody is pre-conjugated to the DNA-label. Assemblage III uses the pre-conjugated detection antibody/ DNA-label but binds the capture antibody through biotin to surface immobilized streptavidin. We found assemblage II to be the most sensitive, with a detection limit of 4.8 X 10(5) PSA molecules. This can be compared to the detection limit of the ELISA, which is 5.7 x 10(7) molecules. Assemblage II was the most reproducible with a standard deviation (SD) of 0.21 cycles, while assemblage I was the least reproducible (SD-0.45 cycles). The SD of assemblage II was 0.25 cycles. We conclude that using pre-conjugated detection antibody/DNA-label enhances both the sensitivity and the reproducibility of real-time immuno-PCR. Measurements of PSA in serum samples using real-time immuno-PCR correlated well with measurements performed with ELISA. The real-time immuno-PCR measurements were more sensitive and the dynamic range was larger than with the ELISA. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:107 / 116
页数:10
相关论文
共 17 条
[1]   A retrospective and prospective overview of prostate-specific antigen [J].
Ablin, RJ .
JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 1997, 123 (11-12) :583-594
[2]   A real-time immuno-PCR assay for routine ultrasensitive quantification of proteins [J].
Adler, M ;
Wacker, R ;
Niemeyer, CM .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2003, 308 (02) :240-250
[3]  
[Anonymous], 1980, ANAL CHEM, V52, P2242
[4]   Lowering the detection limits of HIV-1 viral load using real-time Immuno-PCR for HIV-1 p24 antigen [J].
Barletta, JM ;
Edelman, DC ;
Constantine, NT .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2004, 122 (01) :20-27
[5]  
CHAN MA, 1987, CLIN CHEM, V33, P2000
[6]   ENZYME-LINKED IMMUNOSORBENT ASSAY (ELISA) QUANTITATIVE ASSAY OF IMMUNOGLOBULIN-G [J].
ENGVALL, E ;
PERLMANN, P .
IMMUNOCHEMISTRY, 1971, 8 (09) :871-&
[7]  
Furuya D, 2001, CLIN CHEM, V47, P1475
[8]   Immuno-quantitative polymerase chain reaction for detection and quantitation of prion protein [J].
Gofflot, S ;
El Moualij, BF ;
Zorzi, D ;
Melen, L ;
Roels, S ;
Quatpers, D ;
Grassi, J ;
Vanopdenbosch, E ;
Heinen, E ;
Zorzi, W .
JOURNAL OF IMMUNOASSAY & IMMUNOCHEMISTRY, 2004, 25 (03) :241-258
[9]   Cytokine detection by antibody-based proximity ligation [J].
Gullberg, M ;
Gústafsdóttir, SM ;
Schallmeiner, E ;
Jarvius, J ;
Bjarnegård, M ;
Betsholtz, C ;
Landegren, U ;
Fredriksson, S .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2004, 101 (22) :8420-8424
[10]   THEORETICAL LIMITATIONS ON IMMUNOASSAY SENSITIVITY - CURRENT PRACTICE AND POTENTIAL ADVANTAGES OF FLUORESCENT EU-3+ CHELATES AS NONRADIOISOTOPIC TRACERS [J].
JACKSON, TM ;
EKINS, RP .
JOURNAL OF IMMUNOLOGICAL METHODS, 1986, 87 (01) :13-20