Performance evaluation of spatial compounding in the presence of aberration and adaptive Imaging

被引:3
作者
Dahl, JJ [1 ]
Guenther, D [1 ]
Trahey, GE [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
来源
MEDICAL IMAGING 2003: ULTRASONIC IMAGING AND SIGNAL PROCESSING | 2003年 / 5035卷
关键词
phase aberration; 1.75D Arrays; spatial compounding;
D O I
10.1117/12.479968
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Spatial compounding has been used for years to reduce speckle in ultrasonic images and to resolve anatomical features hidden behind the grainy appearance of speckle. Adaptive imaging restores image contrast and resolution by compensating for beamforming errors caused by tissue-induced phase errors. Spatial compounding represents a form of incoherent imaging, whereas adaptive imaging attempts to maintain a coherent, diffraction-limited aperture in the presence of aberration. Using a Siemens Antares scanner, we acquired single channel RF data on a commercially available 1-D probe. Individual channel RF data was acquired on a cyst phantom in the presence of a near field electronic phase screen. Simulated data was also acquired for both a 1-D and a custom built 8x96, 1.75-D probe (Tetrad Corp.). The data was compounded using a receive spatial compounding algorithm; a widely used algorithm because it takes advantage of parallel beamforming to avoid reductions in frame rate. Phase correction was also performed by using a least mean squares algorithm to estimate the arrival time errors. We present simulation and experimental data comparing the performance of spatial compounding to phase correction in contrast and resolution tasks. We evaluate spatial compounding and phase correction, and combinations of the two methods, under varying aperture sizes, aperture overlaps, and aberrator strength to examine the optimum configuration and conditions in which spatial compounding will provide a similar or better result than adaptive imaging. We find that, in general, phase correction is hindered at high aberration strengths and spatial frequencies, whereas spatial compounding is helped by these aberrators.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 21 条
[1]   SPECKLE IN ULTRASOUND B-MODE SCANS [J].
BURCKHARDT, CB .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (01) :1-6
[2]  
Fernandez A. T., 2002, THESIS DUKE U DURHAM
[3]  
FERNANDEZ AT, 2000, IEEE ULTRASONIC S P, V2, P1659
[4]   PHASE-ABERRATION CORRECTION USING SIGNALS FROM POINT REFLECTORS AND DIFFUSE SCATTERERS - BASIC PRINCIPLES [J].
FLAX, SW ;
ODONNELL, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1988, 35 (06) :758-767
[5]  
GAUSES RC, 2000, P SPIE
[6]  
Jensen J. A., 1996, Medical & Biological Engineering & Computing, V34, P351
[7]   EVALUATIONAL SPATIAL COMPOUNDING [J].
LI, PC ;
ODONNELL, M .
ULTRASONIC IMAGING, 1994, 16 (03) :176-189
[8]   IMPROVED DETECTABILITY WITH BLOCKED ELEMENT COMPENSATION [J].
LI, PC ;
ODONNELL, M .
ULTRASONIC IMAGING, 1994, 16 (01) :1-18
[9]  
LIU D, 2000, IEEE ULTRASONIC S P, V2, P1655
[10]   A COMPARATIVE-EVALUATION OF SEVERAL ALGORITHMS FOR PHASE ABERRATION CORRECTION [J].
NG, GC ;
WORRELL, SS ;
FREIBURGER, PD ;
TRAHEY, GE .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (05) :631-643