Dual photometric-contactless conductometric detector for capillary electrophoresis

被引:78
作者
Chvojka, T [1 ]
Jelínek, I [1 ]
Opekar, F [1 ]
Stulík, K [1 ]
机构
[1] Charles Univ, Dept Analyt Chem, UNESCO, Lab Environm Electrochem, CR-12840 Prague 2, Czech Republic
关键词
capillary electrophoresis; dual detector; photometry; contactless conductometry;
D O I
10.1016/S0003-2670(00)01191-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A combined detection system involving simultaneous absorption photometric and contactless conductometric measurements at the same place of the fused-silica separation capillary has been designed. The measurements are mutually independent and the static and dynamic properties of the detection are fully comparable with those characteristic of individual photometric and conductometric detectors. Optical fibers are used to carry the photometric signal, whereas the conductometric signal is obtained from electrodes placed on the outer side of the capillary wall at a frequency in a range from 100 to 500 kHz. The detector is especially advantageous in analyses of mixtures containing both organic and inorganic ions. The limits of detection (LOD) and dynamic (DR) or linear dynamic (LDR) ranges have been determined for potassium ion (conductometry) and salicylate (photometry), obtaining 3.5 and 20 muM for the LOD, 0.1-5000 and 50-10000 muM for the DR, and 10-50000 and 50-40 000 muM for the LDR, for Kf and salicylate, respectively. The reliability of the detector was demonstrated on an analysis of a real sample of an infusion solution (Vishnevski solution). (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:13 / 21
页数:9
相关论文
共 19 条
  • [1] Characterization of single-isomer, heptasulfated β-cyclodextrins by electrospray ionization mass spectrometry and indirect UV detection capillary electrophoresis
    Bondarenko, PV
    Wolf, B
    Cai, H
    Vincent, JB
    Macfarlane, RD
    Vigh, G
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (14) : 3042 - 3045
  • [2] da Silva JAF, 1998, ANAL CHEM, V70, P4339
  • [3] Rudimentary capillary-electrode alignment for capillary electrophoresis with electrochemical detection
    Fermier, AM
    Gostkowski, ML
    Colon, LA
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (09) : 1661 - 1664
  • [4] FORET F, 1993, CAPILLARY ZONE ELECT, P153
  • [5] HIGH-FREQUENCY CONTACTLESS CONDUCTIVITY DETECTION IN ISOTACHOPHORESIS
    GAS, B
    DEMJANENKO, M
    VACIK, J
    [J]. JOURNAL OF CHROMATOGRAPHY, 1980, 192 (02): : 253 - 257
  • [6] Direct determination of paracetamol and its metabolites in urine and serum by capillary electrophoresis with ultraviolet and mass spectrometric detection
    Heitmeier, S
    Blaschke, G
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1999, 721 (01): : 93 - 108
  • [7] Combination of amperometric detector & UV detector for capillary electrophoresis
    Huang, XJ
    You, TY
    Yang, XR
    Wang, EK
    [J]. TALANTA, 1999, 49 (02) : 425 - 431
  • [8] Simple technique for joining of capillaries in capillary separation methods
    Jelínek, I
    Opekar, F
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 802 (02) : 381 - 384
  • [9] Capillary electrophoresis of inorganic anions
    Kaniansky, D
    Masár, M
    Marák, J
    Bodor, R
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 834 (1-2) : 133 - 178
  • [10] Contactless conductivity detection in capillary zone electrophoresis
    Kaniansky, D
    Zelenská, V
    Masár, M
    Iványi, F
    Gazdíková, S
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) : 349 - 359