Fracture of the cricoid cartilage after Sellick's manoeuvre

被引:34
作者
Heath, KJ
Palmer, M
Fletcher, SJ
机构
[1] Anaesthetic Department, Norfolk and Norwich Hospital, Norwich, Norfolk NR1 3SR, Brunswick Road
关键词
larynx; cricoid pressure; complications; fractured cricoid cartilage;
D O I
10.1093/bja/76.6.877
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We report a case of fracture of the cricoid cartilage associated with cricoid pressure during rapid sequence tracheal intubation in a patient with status asthmaticus. This patient had a history of laryngeal trauma 48 yr previously. Fracture of the cricoid cartilage has not been reported previously after cricoid pressure.
引用
收藏
页码:877 / 878
页数:2
相关论文
共 9 条
[1]  
Colombo E, 1989, Acta Otorhinolaryngol Ital, VSuppl 26, P1
[2]   DIFFICULT TRACHEAL INTUBATION IN OBSTETRICS [J].
CORMACK, RS ;
LEHANE, J .
ANAESTHESIA, 1984, 39 (11) :1105-1111
[3]  
GEORGESCU A, 1992, ANESTH ANALG, V74, P457
[4]   THE APPLICATION OF CRICOID PRESSURE - AN ASSESSMENT AND A SURVEY OF ITS PRACTICE [J].
HOWELLS, TH ;
CHAMNEY, AR ;
WRAIGHT, WJ ;
SIMONS, RS .
ANAESTHESIA, 1983, 38 (05) :457-460
[5]  
MEHROTRA D, 1979, LANCET, V2, P582
[6]  
SELLICK BA, 1961, LANCET, V2, P404
[7]  
Shorten G D, 1991, J Clin Anesth, V3, P403, DOI 10.1016/0952-8180(91)90185-P
[9]   THE DETERMINATION OF AN EFFECTIVE CRICOID PRESSURE [J].
WRAIGHT, WJ ;
CHAMNEY, AR ;
HOWELLS, TH .
ANAESTHESIA, 1983, 38 (05) :461-466