Instant center of rotation estimation using the Reuleaux technique and a Lateral Extrapolation technique

被引:18
作者
Moorehead, JD [1 ]
Montgomery, SC
Harvey, DM
机构
[1] Univ Hosp Aintree, Orthopaed Res Unit, Liverpool L9 7AL, Merseyside, England
[2] Liverpool John Moores Univ, Sch Engn, Liverpool L3 3AF, Merseyside, England
关键词
reuleaux; planar kinematics; pole; knee;
D O I
10.1016/S0021-9290(03)00156-8
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A mathematical model of a rolling wheel was used to investigate the errors encountered when the Reuleaux technique is employed to estimate planar instant centers of rotation (ICRs). The investigation showed that large errors can result when this pole measurement technique is applied to objects rotating more than 12degrees. The investigation also showed that these errors can be substantially reduced by applying a new Lateral Extrapolation technique to the pole data. When the Reuleaux technique is applied to marks on a 10 cm. radius wheel, the resulting offset errors from the ICR are 3.96 cm. for a 45degrees roll and I cm for a 12degrees roll. Following lateral extrapolation, these offset errors reduce to 0.52 cm for the 45degrees roll and less than 0.04 cm for the 12degrees roll. Thus, the extrapolation technique is over seven times more accurate for a 45degrees roll, and over 25 times more accurate for a 12degrees roll. The extrapolation technique has been validated with the model for joints that exhibit both slip and roll, such as the knee. As joint ICR pathway measurement can be used to detect pathology, these accuracy improvements offer potential benefits for clinical applications. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1301 / 1307
页数:7
相关论文
共 17 条
[1]  
BARTON LO, 1984, MECH ANAL SIMPLIFIED, P83
[2]   ONE PARAMETER MODEL FOR ERROR IN INSTANTANEOUS CENTER OF ROTATION MEASUREMENTS [J].
BRYANT, JT ;
WEVERS, HW ;
LOWE, PJ .
JOURNAL OF BIOMECHANICS, 1984, 17 (05) :317-323
[3]   BIOMECHANICS OF INTERNAL DERANGEMENT OF KNEE - PATHOMECHANICS AS DETERMINED BY ANALYSIS OF INSTANT CENTERS OF MOTION [J].
FRANKEL, VH ;
BURSTEIN, AH ;
BROOKS, DB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1971, A 53 (05) :945-&
[4]   BIOMECHANICAL ANALYSIS OF THE KNEE AFTER RUPTURE OF THE ANTERIOR CRUCIATE LIGAMENT AND ITS PRIMARY REPAIR - AN INSTANT-CENTER ANALYSIS OF FUNCTION [J].
GERBER, C ;
MATTER, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1983, 65 (04) :391-399
[5]   MOIRE PATTERNS - AN ACCURATE TECHNIQUE FOR DETERMINATION OF THE LOCUS OF THE CENTERS OF ROTATION [J].
GERTZBEIN, SD ;
CHAN, KH ;
TILE, M ;
SELIGMAN, J ;
KAPASOURI, A .
JOURNAL OF BIOMECHANICS, 1985, 18 (07) :501-+
[6]   BIOMECHANICAL SIGNIFICANCE OF INSTANTANEOUS CENTER OF ROTATION - HUMAN TEMPOROMANDIBULAR JOINT [J].
GRANT, PG .
JOURNAL OF BIOMECHANICS, 1973, 6 (02) :109-113
[7]   INSTANTANEOUS AXIS OF ROTATION AS A FUNCTION OF THE 3 COLUMNS OF THE SPINE [J].
HAHER, TR ;
OBRIEN, M ;
FELMLY, WT ;
WELIN, D ;
PERRIER, G ;
CHOUEKA, J ;
DEVLIN, V ;
VASSILIOU, A ;
CHOW, G .
SPINE, 1992, 17 (06) :S149-S154
[8]  
HARTENBERG R, 1964, KINEMATIC SYNTHESIS, P89
[9]   Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee [J].
Iwaki, H ;
Pinskerova, V ;
Freeman, MAR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (08) :1189-1195
[10]   In vivo measurement-based estimations of the moment arm in the human tibialis anterior muscle-tendon unit [J].
Maganaris, CN .
JOURNAL OF BIOMECHANICS, 2000, 33 (03) :375-379