Identification and susceptibility testing of Enterobacteriaceae and Pseudomonas aeruginosa by direct inoculation from positive BACTEC blood culture bottles into Vitek 2

被引:81
作者
Bruins, MJ [1 ]
Bloembergen, P [1 ]
Ruijs, GJHM [1 ]
Wolfhagen, MJHM [1 ]
机构
[1] Isala Klin, Lab Clin Microbiol & Infect Dis, NL-8021 AM Zwolle, Netherlands
关键词
D O I
10.1128/JCM.42.1.7-11.2004
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Inoculation of an automated system for rapid identification (ID) and antimicrobial susceptibility testing (AST) directly from positive blood culture bottles will reduce the turnaround time of laboratory diagnosis of septicemic patients, which benefits clinical outcome and decreases patient costs. Direct test results, however, must always be confirmed by testing a pure overnight culture, which is the "gold standard." We studied the accuracy of direct testing versus repeat testing in order to investigate the possibility of refraining from repeat testing. We also assessed the clinical risk of reporting results based on direct testing only. We inoculated Vitek 2 (bioMerieux) directly from 410 positive BACTEC 9240 (BD) blood culture bottles containing gram-negative rods and studied the ID and AST results. In a comparison of direct inoculation with the standard method, a total of 344 isolates of Enterobacteriaceae and Pseudomonas aeruginosa were tested, and 93.0% were correctly identified. Of the 39 (10.2%) samples that contained bacilli not identifiable by Vitek 2, only I gave a conclusive, correct result. The overall MIC agreement among 312 isolates was 99.2%, with 0.8% very major and 0.02% major error rates. Of only three (polymicrobial) samples, the direct susceptibility pattern would be reported to the clinician as too sensitive. Vitek 2 results obtained from direct inoculation of blood culture bottles containing gram-negative bacilli are safe enough for immediate reporting, provided that ID and AST are consistent. Repeat testing is not necessary, unless Gram stain or overnight subculture results raise doubt about the purity of the culture.
引用
收藏
页码:7 / 11
页数:5
相关论文
共 22 条
  • [1] [Anonymous], PERF STAND ANT SUSC
  • [2] Clinical and financial benefits of rapid bacterial identification and antimicrobial susceptibility testing
    Barenfanger, J
    Drake, C
    Kacich, G
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (05) : 1415 - 1418
  • [3] CLINICAL IMPACT OF RAPID IN-VITRO SUSCEPTIBILITY TESTING AND BACTERIAL IDENTIFICATION
    DOERN, GV
    VAUTOUR, R
    GAUDET, M
    LEVY, B
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (07) : 1757 - 1762
  • [4] Antimicrobial susceptibility and frequency of occurrence of clinical blood isolates in Europe from the SENTRY Antimicrobial Surveillance Program, 1997 and 1998
    Fluit, AC
    Jones, ME
    Schmitz, FJ
    Acar, J
    Gupta, R
    Verhoef, J
    [J]. CLINICAL INFECTIOUS DISEASES, 2000, 30 (03) : 454 - 460
  • [5] Evaluation of the VITEK 2 system for rapid identification of medically relevant gram-negative rods
    Funke, G
    Monnet, D
    deBernardis, C
    von Graevenitz, A
    Freney, J
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (07) : 1948 - 1952
  • [6] Garcia-Garrote F, 2000, J CLIN MICROBIOL, V38, P2108
  • [7] Evaluation of the Vitek 2 system for rapid identification of clinical isolates of gram-negative bacilli and members of the family Streptococcaceae
    Gavin, PJ
    Warren, JR
    Obias, AA
    Collins, SM
    Peterson, LR
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2002, 21 (12) : 869 - 874
  • [8] Direct identification and susceptibility testing of enteric bacilli from positive blood cultures using VITEK (GNI plus /GNS-GA)
    Hansen, DS
    Jensen, AG
    Norskov-Lauritsen, N
    Skov, R
    Bruun, B
    [J]. CLINICAL MICROBIOLOGY AND INFECTION, 2002, 8 (01) : 38 - 44
  • [9] Vitek GPS card susceptibility testing accuracy using direct inoculation from BACTEC 9240 blood culture bottles
    Howard, WJ
    Buschelman, BJ
    Bale, MJ
    Pfaller, MA
    Koontz, FP
    Jones, RN
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1996, 24 (02) : 109 - 112
  • [10] SELECTION CRITERIA FOR AN ANTIMICROBIAL SUSCEPTIBILITY TESTING SYSTEM
    JORGENSEN, JH
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (11) : 2841 - 2844