Nine-color flow cytometry for accurate measurement of T cell subsets and cytokine responses. Part I: Panel design by an empiric approach

被引:51
作者
McLaughlin, Bridget E. [1 ]
Baumgarth, Nicole [2 ]
Bigos, Martin [3 ]
Roederer, Mario [4 ]
De Rosa, Stephen C. [5 ]
Altman, John D. [6 ]
Nixon, Douglas F.
Ottinger, Janet [7 ,8 ]
Oxford, Carol [9 ]
Evans, Thomas G. [10 ]
Asmuth, David M. [1 ]
机构
[1] Univ Calif Davis, Div Infect Dis, Davis, CA 95616 USA
[2] Univ Calif Davis, Ctr Comparat Med, Davis, CA 95616 USA
[3] Gladstone Inst Virol & Immunol, San Francisco, CA USA
[4] NIAID, NIH, Bethesda, MD 20892 USA
[5] Univ Washington, Fred Hutchinson Canc Res Ctr, Seattle, WA 98195 USA
[6] Emory Univ, Emory Vaccine Ctr Yerkes, Atlanta, GA 30322 USA
[7] Univ Calif San Francisco, Div Expt Med, San Francisco, CA 94143 USA
[8] Duke Univ, Med Ctr, Duke Ctr AIDS Res, Durham, NC USA
[9] Univ Calif Davis, Med Pathol & Lab Med, Davis, CA 95616 USA
[10] Novartis Inst Biol Res, Cambridge, MA USA
关键词
polychromatic flow cytometry; T cell immunophenotyping; fluorochrome conjugated antibody; compensation;
D O I
10.1002/cyto.a.20555
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Polychromatic flow cytometry offers the unprecedented ability to investigate multiple antigens per cell. Unfortunately, unwanted spectral overlaps and compensation problems increase when more than four colors are used, but these problems can be minimized if staining combinations are chosen carefully. We used an empiric approach to design, test and identify six-color T cell immunophenotyping reagent panels that can be expanded to include three or more functional or other markers in the FITC, PE, and APC channels without significant spectral limitations. Thirty different six-color T cell surface antigen reagent panels were constructed to identify major T cell subsets and maturational subtypes as defined by CCR7 and CD45RA expression, while excluding monocytes, B and non-viable cells. Staining performance of each panel was compared on cryopreserved cells from a single healthy donor recorded on a multiparameter cell sorter. Ten of the thirty reagent panels offered reliable resolution of T cell major and maturational surface markers. Of these, two panels were selected that showed the least spectral overlap and resulting background increase in the FITC, PE, and APC channels. These channels were left unoccupied for inclusion of additional phenotypic or functional markers, such as cytokines. Careful reagent titration and testing of multiple candidate panels are necessary to ensure quality results in multiparametric measurements. (C) 2008 International Society for Advancement of Cytometry.
引用
收藏
页码:400 / 410
页数:11
相关论文
共 24 条
[1]
Baumgarth N, 2004, METHOD CELL BIOL, V75, P3
[2]
A practical approach to multicolor flow cytometry for immunophenotyping [J].
Baumgarth, N ;
Roederer, M .
JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 243 (1-2) :77-97
[3]
Quantitative comparison of long-wavelength Alexa Fluor dyes to Cy dyes: Fluorescence of the dyes and their bioconjugates [J].
Berlier, JE ;
Rothe, A ;
Buller, G ;
Bradford, J ;
Gray, DR ;
Filanoski, BJ ;
Telford, WG ;
Yue, S ;
Liu, JX ;
Cheung, CY ;
Chang, W ;
Hirsch, JD ;
Beechem, JM ;
Haugland, RP ;
Haugland, RP .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 2003, 51 (12) :1699-1712
[4]
Bigos A, 1999, CYTOMETRY, V36, P36
[5]
Vaccination in humans generates broad T cell cytokine responses [J].
De Rosa, SC ;
Lu, FX ;
Yu, J ;
Perfetto, SP ;
Falloon, J ;
Moser, S ;
Evans, TG ;
Koup, R ;
Miller, CJ ;
Roederer, M .
JOURNAL OF IMMUNOLOGY, 2004, 173 (09) :5372-5380
[6]
Geisler C, 2004, CRIT REV IMMUNOL, V24, P67
[7]
Optimization and validation of an 8-color intracellular cytokine staining (ICS) assay to quantify antigen-specific T cells induced by vaccination [J].
Horton, Helen ;
Thomas, Evan P. ;
Stucky, Jason A. ;
Frank, Ian ;
Moodie, Zoe ;
Huang, Yunda ;
Chiu, Ya-Lin ;
McElrath, M. Juliana ;
De Rosa, Stephen C. .
JOURNAL OF IMMUNOLOGICAL METHODS, 2007, 323 (01) :39-54
[8]
Dynamics of T lymphocyte responses: Intermediates, effectors, and memory cells [J].
Lanzavecchia, A ;
Sallusto, F .
SCIENCE, 2000, 290 (5489) :92-97
[9]
Flow cytometry controls, instrument setup, and the determination of positivity [J].
Maecker, Holden T. ;
Trotter, Joseph .
CYTOMETRY PART A, 2006, 69A (09) :1037-1042
[10]
Selecting fluorochrome conjugates for maximum sensitivity [J].
Maecker, HT ;
Frey, T ;
Nomura, LE ;
Trotter, J .
CYTOMETRY PART A, 2004, 62A (02) :169-173