A packaging contaminant: Isopropylthioxanthone (ITX) in dairy products

被引:21
作者
Benetti, C. [1 ]
Angeletti, R. [1 ]
Binato, G. [1 ]
Biancardi, A. [2 ]
Biamotto, G. [1 ]
机构
[1] Ist Zooprofilattico Sperimentale Venezie, I-35020 Legnaro, Italy
[2] Ist Zooprofilattico Sperimentale Lombardia & Emil, I-52100 Brescia, Italy
关键词
isopropylthioxanthone (ITX); dairy products; method validation; HPLC-MS;
D O I
10.1016/j.aca.2008.02.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast, simple and very selective liquid chromatography-mass spectrometry (LC-MS) method for the detection of isopropylthioxanthone (ITX) in dairy products has been developed and validated. After addition of an ITX-d(3) as internal standard and a simple extraction from the sample with acetonitrile, the extract was centrifuged and directly injected into the LC-MS system. Chromatographic separation was achieved by means of a Gemini C18 column (100 mm x 2.0 mm i.d. 5 mu m) using a gradient of aqueous 20 mM ammonium formiate at pH 4.5 and methanol as the mobile phase, at a flow rate of 0.25 mL min(-1). The method was validated according to the guidelines laid down by the Commission Decision 2002/657/EC using the parent ion [M+H](+) (m/z 255) as quantification ion, and the fragment ion (m/z 213) obtained by in-source collision-induced dissociation (IS-CID) as confirmation ion. Absolute and relative recoveries rates were verified at 5, 10, 15 mu g kg(-1) in yoghurt samples and at 5 mu g kg(-1) in milk and pudding: mean absolute recoveries were 77% in yoghurt, 50% in pudding and 67% in milk; relative recoveries (after internal standard correction) were always >97% in each matrix. The detection limit (CC alpha) and the detection capability (CC beta) of method were 6.2 and 7.2 mu g kg(-1), respectively. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:132 / 138
页数:7
相关论文
共 11 条
[1]  
BAGNATI R, 1998, RAPID COMMUN MASS SP, V21
[2]   Determination of 2-isopropyl thioxanthone and 2-ethylhexyl-4-dimethylaminobenzoate in milk:: comparison of gas and liquid chromatography with mass spectrometry [J].
Gil-Vergara, Ana ;
Blasco, Cristina ;
Pico, Yolanda .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (02) :605-617
[3]  
*ISO, 2000, ISO11843
[4]   Determination of isopropylthioxanthone (ITX) in milk, yoghurt and fat by HPTLC-FLD, HPTLC-ESI/MS and HPTLC-DART/MS [J].
Morlock, Gertrud ;
Schwack, Wolfgang .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (03) :586-595
[5]   Analysis of food packaging UV inks for chemicals with potential to migrate into food simulants [J].
Papilloud, S ;
Baudraz, D .
FOOD ADDITIVES AND CONTAMINANTS, 2002, 19 (02) :168-175
[6]  
*RASFF, 2005, 1782002 RASFF
[7]   ELISA qualitative screening of chloramphenicol in muscle, eggs, honey and milk: method validation according to the Commission Decision 2002/657/EC criteria [J].
Scortichini, G ;
Annunziata, L ;
Haouet, MN ;
Benedetti, F ;
Krusteva, I ;
Galarini, R .
ANALYTICA CHIMICA ACTA, 2005, 535 (1-2) :43-48
[8]   Determination of isopropyl-9H-thioxanthen-9-one in packaged beverages by solid-phase extraction clean-up and liquid chromatography with tandem mass spectrometry detection [J].
Sun, Cuilian ;
Chan, Sheot Ham ;
Lu, Dan ;
Lee, Hui Min Wendy ;
Bloodworth, Bosco Chen .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1143 (1-2) :162-167
[9]   RUGGEDNESS TESTS ON THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ASSAY OF THE UNITED-STATES-PHARMACOPEIA-XXII FOR TETRACYCLINE HYDROCHLORIDE - A COMPARISON OF EXPERIMENTAL-DESIGNS AND STATISTICAL INTERPRETATIONS [J].
VANDERHEYDEN, Y ;
LUYPAERT, K ;
HARTMANN, C ;
MASSART, DL ;
HOOGMARTENS, J ;
DEBEER, J .
ANALYTICA CHIMICA ACTA, 1995, 312 (03) :245-262
[10]  
Youden WJ, 1975, STAT MANUAL AOAC, P35