Reuse-associated mortality in incident hemodialysis patients in the United States, 2000 to 2001

被引:12
作者
Fan, Q
Liu, JN
Ebben, JP
Collins, AJ
机构
[1] Minneapolis Med Res Fdn Inc, Chron Dis Res Grp, Minneapolis, MN 55404 USA
[2] Univ Minnesota, Dept Med, Minneapolis, MN 55455 USA
关键词
dialysis; end-stage renal disease (ESRD); mortality; reuse;
D O I
10.1053/j.ajkd.2005.07.017
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background The impact of dialyzer reuse on the mortality of hemodialysis patients is debated. This study assesses reuse-associated mortality across US dialysis provider systems (for-profit, not-for-profit; hospital-based, and freestanding units) in incident patients. Methods: Incident Medicare hemodialysis patients who initiated dialysis therapy from January 1, 2000, to December 31,2001, were included and followed up to December 31,2002. A 3-month entry period was used to determine comorbidity and disease severity. Applying various analytic approaches, mortality rates for patients treated with reused (or reprocessed) or single-use dialyzers were compared. Because of differences among dialysis units, facility clustering was addressed. Results: Of 75,831 patients, 61,391 patients (81.0%) were classified as on reuse, and 14,440 patients (19.0%), as on single use, as of the start of follow-up. The overall mortality rate was 25.0/100 patient-years. No difference in mortality risk was found between patients treated with reuse compared with single use in an intent-to-treat approach (hazard ratio, 0.98; 95% confidence interval, 0.94 to 1.02; P = 0.266) after adjusting for chain affiliation, for-profit status, year of dialysis inception, age, sex, race, renal diagnosis, comorbidity, and hospitalization days. Findings were similar in an as-treated approach (hazard ratio, 0.97; 95% confidence interval, 0.93 to 1.01; P = 0.136). No survival advantage associated with single use was found for subgroups. Conclusion: No overall survival advantage or disadvantage is associated with dialyzer reuse compared with single use in incident hemodialysis patients in the United States; however, continued monitoring is advised.
引用
收藏
页码:661 / 668
页数:8
相关论文
共 21 条
[1]  
Arduino MJ, 1998, SEMIN DIALYSIS, V11, P282, DOI 10.1111/j.1525-139X.1998.tb00368.x
[2]  
Bok D V, 1980, Proc Clin Dial Transplant Forum, V10, P92
[3]   Effects of high-flux Hemodialysis on clinical outcomes: Results of the HEMO study [J].
Cheung, AK ;
Levin, NW ;
Greene, T ;
Agodoa, L ;
Bailey, J ;
Beck, G ;
Clark, W ;
Levey, AS ;
Leypoldt, JK ;
Ornt, DB ;
Rocco, MV ;
Schulman, G ;
Schwab, S ;
Teehan, B ;
Eknoyan, G .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2003, 14 (12) :3251-3263
[4]   Dialyser reuse-associated mortality in incident Medicare haemodialysis and hospitalization risk patients, 1998-1999 [J].
Collins, AJ ;
Liu, JN ;
Ebben, JP .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2004, 19 (05) :1245-1251
[5]  
Daugirdas J T, 1988, Kidney Int Suppl, V24, pS37
[6]  
*DEP HLTH HUM SERV, 2004, AM J KIDNEY DIS, V44, P5
[7]   Impact of disease severity and hematocrit level on reuse-associated mortality [J].
Ebben, JP ;
Dalleska, F ;
Ma, JZ ;
Everson, SE ;
Constantini, EG ;
Collins, AJ .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2000, 35 (02) :244-249
[8]   Effect of dialysis dose and membrane flux in maintenance hemodialysis. [J].
Eknoyan, G ;
Beck, GJ ;
Cheung, AK ;
Daugirdas, JT ;
Greene, T ;
Kusek, JW ;
Allon, M ;
Bailey, J ;
Delmez, JA ;
Depner, TA ;
Dwyer, JT ;
Levey, AS ;
Levin, NW ;
Milford, E ;
Ornt, DB ;
Rocco, MV ;
Schulman, G ;
Schwab, SJ ;
Teehan, BP ;
Toto, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (25) :2010-2019
[9]  
EKNOYAN G, 1997, CLIN PRACTICE GUIDEL
[10]   Effect of dialyzer reuse on survival of patients treated with hemodialysis [J].
Feldman, HI ;
Kinosian, M ;
Bilker, WB ;
Simmons, C ;
Holmes, JH ;
Pauly, MV ;
Escarce, JJ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (08) :620-625