Trapping of microparticles in the near field of an ultrasonic transducer

被引:106
作者
Lilliehorn, T
Simu, U
Nilsson, M
Almqvist, M
Stepinski, T
Laurell, T
Nilsson, J
Johansson, S
机构
[1] Uppsala Univ, Dept Engn Sci, SE-75121 Uppsala, Sweden
[2] Lund Inst Technol, Dept Elect Measurement Technol, Lund, Sweden
关键词
ultrasound; near field; trap; piezoelectric; PZT; microfluidic; particles;
D O I
10.1016/j.ultras.2004.11.001
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We are investigating means of handling microparticles in microfluidic systems, in particular localized acoustic trapping of microparticles in a flow-through device. Standing ultrasonic waves were generated across a microfluidic channel by ultrasonic microtransducers integrated in one of the channel walls. Particles in a fluid passing a transducer were drawn to pressure minima in the acoustic field, thereby being trapped and confined at the lateral position of the transducer. The spatial distribution of trapped particles was evaluated and compared with calculated acoustic intensity distributions. The particle trapping was found to be strongly affected by near field pressure variations due to diffraction effects associated with the finite sized transducer element. Since laterally confining radiation forces are proportional to gradients in the acoustic energy density, these near field pressure variations may be used to get strong trapping forces, thus increasing the lateral trapping efficiency of the device. In the experiments, particles were successfully trapped in linear fluid flow rates up to 1 mm/s. It is anticipated that acoustic trapping using integrated transducers can be exploited in miniaturised total chemical analysis systems (mu TAS), where e.g. microbeads with immobilised antibodies can be trapped in arrays and subjected to minute amounts of sample followed by a reaction, detected using fluorescence. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:293 / 303
页数:11
相关论文
共 28 条
[1]   High resolution light diffraction tomography:: nearfield measurements of 10 MHz continuous wave ultrasound [J].
Almqvist, P ;
Holm, A ;
Jansson, T ;
Persson, HW ;
Lindström, K .
ULTRASONICS, 1999, 37 (05) :343-353
[2]   Micromachined flow-through filter-chamber for chemical reactions on beads [J].
Andersson, H ;
van der Wijngaart, W ;
Enoksson, P ;
Stemme, G .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 67 (1-2) :203-208
[3]  
[Anonymous], 2002, FUNDAMENTALS APPL UL
[4]   RESONANCE SPLITTING IN ULTRASONIC SPECTROSCOPY [J].
COUCHMAN, JC ;
CHANG, FH ;
YEE, BGW ;
BELL, JR .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (05) :293-300
[5]  
Ekström S, 2002, PROTEOMICS, V2, P413, DOI 10.1002/1615-9861(200204)2:4<413::AID-PROT413>3.0.CO
[6]  
2-1
[7]   MULTILAYER PIEZOELECTRIC CERAMICS FOR 2-DIMENSIONAL ARRAY TRANSDUCERS [J].
GOLDBERG, RL ;
SMITH, SW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (05) :761-771
[8]  
Goodman J.W., 1996, Opt. Eng, V35, P1513, DOI DOI 10.1016/J.APSUSC.2017.08.033
[9]  
Groschl H, 1998, ACUSTICA, V84, P815
[10]  
Groschl M, 1998, ACUSTICA, V84, P632