Non-invasive cardiac output determination: Comparison of a new partial-rebreathing technique with thermodilution

被引:28
作者
Binder, JC
Parkin, WG
机构
[1] Monash Med Ctr, Dept Resp Med, Melbourne, Vic, Australia
[2] Monash Med Ctr, Dept Intens Care, Melbourne, Vic, Australia
[3] Monash Univ, Ctr Heart & Chest Res, Melbourne, Vic 3004, Australia
关键词
cardiac output; measurement; fick; differential; derivative;
D O I
10.1177/0310057X0102900103
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This study compares a derivative Fick technique using carbon dioxide (CO2) with the thermodilution pulmonary artery catheter (PAC), for determination of cardiac output (CO). Subjects were sedated mechanically ventilated adults following elective cardiac surgery. Microprocessor controlled deadspace activation and side-stream capnography in a ventilator circuit enabled calculation of CO (COCO2) every four minutes. Thermodilution CO (COTD) was performed as clinically indicated and at 20-minute intervals. Simultaneous COTD/COCO2 pairs were recorded from time of admission to ICU for a minium period of two hours for each patient. There were 358 COTD/COCO2 pairs recorded from 41 patients. Cardiac output measurements ranged from 2.7 to 10.6 l/min. The bias (Bland-Altman) was 0.050 l/min (95% CI -0.024 to 0.125 l/min). The 95% limits of agreement were -1.354 to 1.455 l/min. This simple, non-invasive partial-rebreathing technique is a valid alternative to thermodilution for car dine output determination in sedated mechanically ventilated patients. There are significant implications for improved safety reduced complexity and reduced cost in anaesthesia and intensive care.
引用
收藏
页码:19 / 23
页数:5
相关论文
共 14 条
[1]   NONINVASIVE PULMONARY BLOOD-FLOW MEASUREMENT BY MEANS OF CO2 ANALYSIS OF EXPIRATORY GASES [J].
BOSMAN, RJ ;
STOUTENBEEK, CP ;
ZANDSTRA, DF .
INTENSIVE CARE MEDICINE, 1991, 17 (02) :98-102
[2]   NONINVASIVE MEASUREMENT OF CARDIAC-OUTPUT USING PARTIAL CO2 REBREATHING [J].
CAPEK, JM ;
ROY, RJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (09) :653-661
[3]   EVALUATION OF RIGHT-HEART CATHETERIZATION IN THE CRITICALLY ILL PATIENT WITHOUT ACUTE MYOCARDIAL-INFARCTION [J].
CONNORS, AF ;
MCCAFFREE, DR ;
GRAY, BA .
NEW ENGLAND JOURNAL OF MEDICINE, 1983, 308 (05) :263-267
[4]   The effectiveness of right heart catheterization in the initial care of critically ill patients [J].
Connors, AF ;
Speroff, T ;
Dawson, NV ;
Thomas, C ;
Harrell, FE ;
Wagner, D ;
Desbiens, N ;
Goldman, L ;
Wu, AW ;
Califf, RM ;
Fulkerson, WJ ;
Vidaillet, H ;
Broste, S ;
Bellamy, P ;
Lynn, J ;
Knaus, WA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11) :889-897
[5]   Partial carbon dioxide rebreathing: A reliable technique for noninvasive measurement of nonshunted pulmonary capillary blood flow [J].
deAbreu, MG ;
Quintel, M ;
Ragaller, M ;
Albrecht, DM .
CRITICAL CARE MEDICINE, 1997, 25 (04) :675-683
[6]   A NEW METHOD FOR NON-INVASIVE BEDSIDE DETERMINATION OF PULMONARY BLOOD-FLOW [J].
GEDEON, A ;
FORSLUND, L ;
HEDENSTIERNA, G ;
ROMANO, E .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1980, 18 (04) :411-418
[7]   INTEROBSERVER VARIABILITY IN THE INTERPRETATION OF PULMONARY-ARTERY CATHETER PRESSURE TRACINGS [J].
KOMADINA, KH ;
SCHENK, DA ;
LAVEAU, P ;
DUNCAN, CA ;
CHAMBERS, SL .
CHEST, 1991, 100 (06) :1647-1654
[8]   Noninvasive determination of cardiac output in patients with severe airflow limitation [J].
Lands, LC ;
Canny, G ;
Xu, F ;
Coates, AL .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 153 (03) :981-984
[9]  
MCHARDY GJR, 1967, CLIN SCI, V32, P299
[10]   ERRORS IN THE MEASUREMENT OF CARDIAC-OUTPUT BY THERMODILUTION [J].
NISHIKAWA, T ;
DOHI, S .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1993, 40 (02) :142-153