Performance analysis of a compressor driven metal hydride cooling system

被引:29
作者
Bedbak, SS [1 ]
Gopal, MR [1 ]
机构
[1] Indian Inst Technol, Dept Mech Engn, Kharagpur 721302, W Bengal, India
关键词
metal hydrides; compressor; irreversibility; COP; second law efficiency;
D O I
10.1016/j.ijhydene.2004.10.014
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A compressor-driven metal hydride cooling system is analyzed in terms of its energetic and exergetic efficiencies. Applying the first and second laws of thermodynamics, the system COP, contribution of individual irreversibilities and the second law efficiency of the system are obtained. Effects of important design and operating parameters on system performance are presented. Performance comparison is made between systems working with established metal hydrides (MmNi(4.5)Al(0.5) and Fe0.85Mn0.15Ti) and an assumed metal hydride of high hydrogen storage capacity. Studies reveal that the system performance depends mainly on the temperature drops at the high- and low-temperature reactors and compressor efficiency. It is observed that when the temperature drops are high, there is no significant difference between the well-established hydrides and the assumed hydride. It is observed that in order to compete with commercially available vapour compression refrigeration systems in terms of performance, the metal hydride reactors need to be designed for minimum temperature difference between the external medium and the hydride beds. (c) 2004 International Association for Hydrogen Energy. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1127 / 1137
页数:11
相关论文
共 16 条
[1]  
Chen J, 2001, EXERGY, V1, P100, DOI DOI 10.1016/S1164-0235(01)00015-2
[2]  
Golben P., 1989, DESIGN FABRICATE MET
[3]   Experiments on a metal hydride cooling system working with ZrMnFe/MmNi4.5Al0.5 pair [J].
Gopal, MR ;
Murthy, SS .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1999, 22 (02) :137-149
[4]  
Gruen D. M., 1979, Hydrogen Energy System, P1931
[5]   Exergy analysis of multistage cascade refrigeration cycle used for natural gas liquefaction [J].
Kanoglu, M .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2002, 26 (08) :763-774
[6]   Thermal analysis of the Ca0.4Mm0.6Ni5 metal-hydride reactor [J].
Kim, KJ ;
Lloyd, GM ;
Feldman, KT ;
Razani, A .
APPLIED THERMAL ENGINEERING, 1998, 18 (12) :1325-1336
[7]   Compressor-driven metal-hydride heat pumps [J].
Kim, KJ ;
Feldman, KT ;
Lloyd, G ;
Razani, A .
APPLIED THERMAL ENGINEERING, 1997, 17 (06) :551-560
[8]   CONSERVATION OF ENERGY ESTIMATED BY 2ND LAW ANALYSIS OF A POWER-CONSUMING PROCESS [J].
LEIDENFROST, W ;
LEE, KH ;
KORENIC, B .
ENERGY, 1980, 5 (01) :47-61
[9]  
MCCLAINE AW, 1977, Patent No. 4039023
[10]   OPERATING CHARACTERISTICS OF A METAL HYDRIDE HEAT-PUMP FOR GENERATING COOLED AIR [J].
NAGEL, M ;
KOMAZAKI, Y ;
UCHIDA, M ;
SUDA, S ;
MATSUBARA, Y .
JOURNAL OF THE LESS-COMMON METALS, 1984, 104 (02) :307-318