Kinetic determination of trace cobalt(II) by visual autocatalytic indication

被引:14
作者
Endo, M [1 ]
Abe, S
Deguchi, Y
Yotsuyanagi, T
机构
[1] Yamagata Univ, Dept Mat Sci & Engn, Yonezawa, Yamagata 992, Japan
[2] Tohoku Univ, Dept Mol Chem & Engn, Sendai, Miyagi 98077, Japan
关键词
autocatalytic indication reaction; autocatalytic oxidation of cobalt(III)-pyridilazo dye complex; automultiplication of catalyst; kinetic determination of urinary cobalt; visual method of analysis;
D O I
10.1016/S0039-9140(98)00139-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive and simple visual autocatalytic method has been developed for the determination of trace cobalt. The cobalt ion released by the oxidative decomposition of inert bis[2-(5-bromo-2-pyridylazo)-5-(N-propyl-N-sulfo-propyl-amino-phenolato] cobaltate (Co(III)-5-Br-PAPS) with peroxomonosulfate acts as a catalyst for the oxidative degradation of the complex. Thus a definite time lapse of degradation is observed by the sudden disappearance of colored Co(III) complexes. The degradation time varies inversely with the logarithm of the initial concentration of cobalt(II). The determination range of cobalt(II) was from 3 x 10(-9) to 2 x 10(-7) M in the presence of 5 x 10(-6) M of 5-Br-PAPS. The relative standard deviation of the spot size method (10 mu l) was 3.5% at 1 x 10(-7) M cobalt(LT). This autocatalytic indicator reaction system has been successfully applied for the visual determination of urinary cobalt. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:349 / 353
页数:5
相关论文
共 6 条
[1]   A SIMPLE ANALYTICAL METHOD FOR MONITORING THE TOTAL CONCENTRATION OF HEAVY-METAL IONS IN ENVIRONMENTAL WATERS [J].
ABE, S ;
KANNO, A ;
HASEGAWA, K ;
ENDO, M .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1990, 42 (1-4) :45-52
[2]   KINETIC SPECTROPHOTOMETRIC METHOD FOR THE DETERMINATION OF URINARY COBALT-BASED ON ITS CATALYTIC EFFECT ON THE OXIDATION OF L-ADRENALINE HYDROCHLORIDE BY HYDROGEN-PEROXIDE [J].
ANGELOVA, MG ;
ALEXIEV, AA .
ANALYTICA CHIMICA ACTA, 1994, 290 (03) :363-369
[3]   Autocatalytic decomposition of cobalt complexes as an indicator system for the determination of trace amounts of cobalt and effectors [J].
Endo, M ;
Ishihara, M ;
Yotsuyanagi, T .
ANALYST, 1996, 121 (04) :391-394
[4]   AN AUTOCATALYTIC CONSTANT SENSITIVITY DETECTION SYSTEM FOR CATALYSTS AND INFECTORS [J].
ISHIHARA, M ;
ENDO, M ;
IGARASHI, S ;
YOTSUYANAGI, T .
CHEMISTRY LETTERS, 1995, (05) :349-350
[5]  
Kawakubo S, 1996, BUNSEKI KAGAKU, V45, P965
[6]  
QIHUA C, 1989, TALANTA, V36, P65