Repeatability and reproducibility of retention data and band profiles on reversed-phase liquid chromatographic columns II.: Results obtained with Symmetry C18 columns

被引:71
作者
Kele, M
Guiochon, G [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Div Chem & Analyt Sci, Oak Ridge, TN 37831 USA
关键词
retention data; band profiles; stationary phases; LC; symmetry C-18 columns;
D O I
10.1016/S0021-9673(98)00758-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The long-term repeatability, the column-to-column and the lot-to-lot reproducibilities of the retention and profile of the peaks obtained with 15 different Symmetry C-18 columns were investigated. This packing material is an octadecyl bonded silica for RP-LC. Data characterizing the retention, the steric selectivity, the hydrogen bonding capacity, the hydrophobic interaction selectivity, the column efficiency, and the peak asymmetry are reported for a group of 30 neutral, acidic and basic compounds selected as probes. These data were acquired under five different sets of chromatographic conditions, using an HP 1100 liquid chromatograph and following an experimental protocol previously described. Statistical comparison of five different columns of one batch and of columns representative of 10 different batches are based on the high precision data obtained. For example, for 28 of the 30 components, the R.S.D.s of the retention factors measured on 10 columns from as many different batches were better than 2%. The R.S.D.s of the separation factors for 27 of these 30 components were below 1.4%. Such a level of column reproducibility is most impressive. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:55 / 79
页数:25
相关论文
共 10 条
[1]  
Felinger A., 1998, DATA ANAL SIGNAL PRO
[2]   Repeatability and reproducibility of retention data and band profiles on reversed-phase liquid chromatography columns I. Experimental protocol [J].
Kele, M ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1999, 830 (01) :41-54
[3]   CHROMATOGRAPHIC CHARACTERIZATION OF SILICA-C-18 PACKING MATERIALS - CORRELATION BETWEEN A PREPARATION METHOD AND RETENTION BEHAVIOR OF STATIONARY PHASE [J].
KIMATA, K ;
IWAGUCHI, K ;
ONISHI, S ;
JINNO, K ;
EKSTEEN, R ;
HOSOYA, K ;
ARAKI, M ;
TANAKA, N .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1989, 27 (12) :721-728
[4]  
KISELEV AV, 1970, GAS ADSORPTION CHROM
[6]   SHAPE SELECTIVITY IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY FOR THE SEPARATION OF PLANAR AND NONPLANAR SOLUTES [J].
SANDER, LC ;
WISE, SA .
JOURNAL OF CHROMATOGRAPHY A, 1993, 656 (1-2) :335-351
[7]  
UNGER KK, 1990, PACKINGS STATIONARY
[8]  
VERZELE M, 1986, PREPARATIVE HIGH PER
[9]  
1997, MANUAL OPERATIONAL Q
[10]  
[No title captured]