An adaptive microwave phased array for targeted heating of deep tumours in intact breast: animal study results

被引:54
作者
Fenn, AJ [1 ]
Wolf, GL
Fogle, RM
机构
[1] MIT, Lincoln Lab, Lexington, MA 02420 USA
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Ctr Imaging & Pharmaceut Res, Charlestown, MA 02129 USA
关键词
hyperthermia; adaptive phased array; breast cancer; animal trials; temperature distribution;
D O I
10.1080/026567399285846
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
It has previously been reported in phantoms, that an adaptive radiofrequency phased array can generate deep focused heating distributions without overheating the skin and superficial healthy tissues. The present study involves adaptive microwave phased array hyperthermia tests in animals (rabbits) with and without tumours. The design of the adaptive phased array as applied to the treatment of tumours in intact breast, is described. The adaptive phased array concept uses breast compression and dual-opposing 915 MHz air-cooled waveguide applicators with electronic phase shifters and electric-field feedback, to focus automatically by computer control the microwave radiation in deep tissue. Temperature measurements for a clinical adaptive phased array hyperthermia system demonstrate tissue heating at depth with reduced skin heating.
引用
收藏
页码:45 / 61
页数:17
相关论文
共 68 条
[1]   LOCALLY ADVANCED BREAST-CANCER - DEFINING AN OPTIMUM TREATMENT REGIMEN [J].
AHERN, V ;
BARRACLOUGH, B ;
BOSCH, C ;
LANGLANDS, A ;
BOYAGES, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (04) :867-875
[2]   A PREDICTIVE-ADAPTIVE, MULTIPOINT FEEDBACK CONTROLLER FOR LOCAL HEAT THERAPY OF SOLID TUMORS [J].
BABBS, CF ;
VAGUINE, VA ;
JONES, JT .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1986, 34 (05) :604-611
[3]   Stereotactic core-needle biopsy of the breast: A report of the joint task force of the American College of Radiology, American College of Surgeons, and College of American Pathologists [J].
Bassett, L ;
Winchester, DP ;
Caplan, RB ;
Dershaw, DD ;
Dowlatshahi, K ;
Evans, WP ;
Fajardo, LL ;
Fitzgibbons, PL ;
Henson, DE ;
Hutter, RVP ;
Morrow, M ;
Paquelet, JR ;
Singletary, SE ;
Curry, J ;
WilcoxBuchalla, P ;
Zinninger, M .
CA-A CANCER JOURNAL FOR CLINICIANS, 1997, 47 (03) :171-+
[4]   OPTIMAL EXCITATION OF MULTIAPPLICATOR SYSTEMS FOR DEEP REGIONAL HYPERTHERMIA [J].
BOAG, A ;
LEVIATAN, Y .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (10) :987-995
[5]   EARLY BREAST-CANCER - PREDICTORS OF BREAST RECURRENCE FOR PATIENTS TREATED WITH CONSERVATIVE SURGERY AND RADIATION-THERAPY [J].
BOYAGES, J ;
RECHT, A ;
CONNOLLY, JL ;
SCHNITT, SJ ;
GELMAN, R ;
KOOY, H ;
LOVE, S ;
OSTEEN, RT ;
CADY, B ;
SILVER, B ;
HARRIS, JR .
RADIOTHERAPY AND ONCOLOGY, 1990, 19 (01) :29-41
[6]   915 MHZ MICROWAVE INTERSTITIAL HYPERTHERMIA .2. ARRAY OF PHASE-MONITORED ANTENNAS [J].
CAMART, JC ;
DUBOIS, L ;
FABRE, JJ ;
VANLOOT, D ;
CHIVE, M .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1993, 9 (03) :445-454
[7]  
CHAUDHARY SS, 1984, INDIAN J BIOCHEM BIO, V21, P76
[8]   DUAL-BEAM TEM APPLICATOR FOR DIRECT-CONTACT HEATING OF DIELECTRICALLY ENCAPSULATED MALIGNANT MOUSE TUMOR [J].
CHEUNG, AY ;
DAO, T ;
ROBINSON, JE .
RADIO SCIENCE, 1977, 12 (06) :81-85
[9]  
Compton R. T., 1988, Adaptive Antennas: Concepts and Performance
[10]   PHASED-ARRAY DESIGN CONSIDERATIONS FOR DEEP HYPERTHERMIA THROUGH LAYERED TISSUE [J].
CUDD, PA ;
ANDERSON, AP ;
HAWLEY, MS ;
CONWAY, J .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1986, 34 (05) :526-531