Motion-compensated reconstruction of tomographic image sequences

被引:31
作者
Gravier, EJ [1 ]
Yang, YY [1 ]
机构
[1] IIT, Dept Elect & Comp Engn, Chicago, IL 60616 USA
基金
美国国家卫生研究院;
关键词
expectation-maximization (EM) algorithm; image reconstruction; motion compensation; single photon emission computed tomography (SPECT) perfusion imaging; spatiotemporal processing;
D O I
10.1109/TNS.2004.843092
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, we study a motion-compensated approach for simultaneous reconstruction of image frames in a time sequence. We treat the frames in a sequence collectively as a single function of both space and time, and define a temporal prior to account for the temporal correlations in a sequence. This temporal prior is defined in a form of motion-compensation, aimed to follow the curved trajectories of the object motion through space-time. The image frames are then obtained through estimation using the expectation-maximization (EM) algorithm. The proposed algorithm was evaluated using the four-dimensional (4-D) gated mathematical cardiac-torso (gMCAT) D1.01 phantom to simulate gated single photon emission computed tomography (SPECT) perfusion imaging with Tc-99m-sestamibi. Our experimental results demonstrate that the use of motion compensation for reconstruction can lead to significant improvement in image quality and reconstruction accuracy.
引用
收藏
页码:51 / 56