Real-time three-dimensional dobutamine stress echocardiography in assessment of ischemia: Comparison with two-dimensional dobutamine stress echocardiography

被引:103
作者
Ahmad, M [1 ]
Xie, TR [1 ]
McCulloch, M [1 ]
Abreo, G [1 ]
Runge, M [1 ]
机构
[1] Univ Texas, Med Branch, Div Cardiol, Galveston, TX 77555 USA
关键词
D O I
10.1016/S0735-1097(01)01159-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study was designed to test the feasibility and efficacy of using real-time three-dimensional echocardiography (RT-3D) to detect ischemia during dobutamine-induced stress (DSE) and compares the results with conventional two-dimensional echocardiography (2D). BACKGROUND Real-time three-dimensional echocardiography, a novel imaging technique, offers rapid acquisition with multiple simultaneous views of the left ventricle (LV). These features make it attractive for application during stress. METHODS Of 279 consecutive patients screened fbr image quality by 2D, 253 patients with adequate images underwent RT-3D and 2D within 30 s of each other at baseline and at peak DSE. RESULTS Real-time three-dimensional echocardiography and 2D showed good concordance in detection of abnormal LV wall motion at baseline (84%: Kappa = 0.59) and at peak DSE (88.9%: Kappa = 0.72). Left ventricular wall motion scores were similar at baseline and peak DSE using both techniques. Interobserver agreements for detection of ischemia at peak DSE were superior for RT-3D, 92.7% compared with 84.6% for 2D (p < 0.05). Mean scanning time at peak stress by RT-3D in 50 randomly selected patients was shorter, 27.4 +/- 10.7 s compared with 62.4 +/- 20.1 s by 2D (p < 0.0001). In 90 patients with coronary angiograms, RT-3D had a sensitivity of 87.9% in the detection of coronary artery disease (CAD) compared with 79.3% by 2D. CONCLUSIONS Real-time three-dimensional dobutamine stress echocardiography is feasible and sensitive in the detection of CAD. The procedure offers shorter scanning time, superior interobserver agreements and unique new views of the LV. (J Am Coil Cardiol 2001;37:1303-9) (C) 2001 by the American College of Cardiology.
引用
收藏
页码:1303 / 1309
页数:7
相关论文
共 18 条
[1]   Assessment of regional wall motion abnormalities with real-time 3-dimensional echocardiography [J].
Collins, M ;
Hsieh, A ;
Ohazama, CJ ;
Ota, T ;
Stetten, G ;
Donovan, CL ;
Kisslo, J ;
Ryan, T .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (01) :7-14
[2]   Methodology, feasibility, safety and diagnostic accuracy of dobutamine stress echocardiography [J].
Geleijnse, ML ;
Fioretti, PM ;
Roelandt, JRTC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (03) :595-606
[3]   ASSESSMENT OF CARDIAC-FUNCTION BY 3-DIMENSIONAL ECHOCARDIOGRAPHY COMPARED WITH CONVENTIONAL NONINVASIVE METHODS [J].
GOPAL, AS ;
SHEN, ZQ ;
SAPIN, PM ;
KELLER, AM ;
SCHNELLBAECHER, MJ ;
LEIBOWITZ, DW ;
AKINBOBOYE, OO ;
RODNEY, RA ;
BLOOD, DK ;
KING, DL .
CIRCULATION, 1995, 92 (04) :842-853
[4]   ACCURACY OF DOBUTAMINE STRESS ECHOCARDIOGRAPHY IN DETECTING CORONARY-ARTERY DISEASE [J].
MARCOVITZ, PA ;
ARMSTRONG, WF .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (16) :1269-1273
[5]   DOBUTAMINE STRESS ECHOCARDIOGRAPHY FOR DETECTION AND ASSESSMENT OF CORONARY-ARTERY DISEASE [J].
MAZEIKA, PK ;
NADAZDIN, A ;
OAKLEY, CM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (06) :1203-1211
[6]   DYNAMIC 3-DIMENSIONAL ECHOCARDIOGRAPHY - METHODS AND CLINICAL POTENTIAL [J].
PANDIAN, NG ;
ROELANDT, J ;
NANDA, NC ;
SUGENG, L ;
CAO, QL ;
AZEVEDO, J ;
SCHWARTZ, SL ;
VANNAN, MA ;
LUDOMIRSKI, A ;
MARX, G ;
VOGEL, M .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1994, 11 (03) :237-259
[7]  
PELLIKKA PA, 1995, MAYO CLIN PROC, V70, P16
[8]   DOBUTAMINE STRESS ECHOCARDIOGRAPHY FOR ASSESSMENT OF PERIOPERATIVE CARDIAC RISK IN PATIENTS UNDERGOING MAJOR VASCULAR-SURGERY [J].
POLDERMANS, D ;
FIORETTI, PM ;
FORSTER, T ;
THOMSON, IR ;
BOERSMA, E ;
ELSAID, EM ;
DUBOIS, NAJJ ;
ROELANDT, JRTC ;
VANURK, H .
CIRCULATION, 1993, 87 (05) :1506-1512
[9]  
RAMM OTV, 1991, IEEE T ULTRASONIC FE, V38, P100
[10]  
RAMM OTV, 1990, J DIGIT IMAGING, P3261