Ex vivo testing of heparin-coated extracorporeal circuits:: bovine experiments

被引:9
作者
Weerwind, PW
Van der Veen, FH
Lindhout, T
De Jong, DS
Cahalan, FT
机构
[1] Univ Nijmegen Hosp, Dept Extra Corp Circulat 414, NL-6500 HB Nijmegen, Netherlands
[2] Maastricht Univ, Dept Cardiol, Maastricht, Netherlands
[3] Maastricht Univ, Dept Biochem, Maastricht, Netherlands
[4] Univ Hosp Maastricht, Dept Cardiothorac Surg, Maastricht, Netherlands
[5] Bakken Res Ctr, Maastricht, Netherlands
关键词
heparin coating; thrombogenicity; extracorporeal life support; calves; heparin activity; fibrinopeptide A;
D O I
10.1177/039139889802100511
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study the intrinsic thrombogenicity of the extracorporeal circuits and the benefit of heparin-bonded circuits in an extracorporeal life support system without full systemic heparinization and with minimal interference of the so called material-independent factors was tested in four calves. In two circuits (group A) all blood-contacting surfaces were coated with end-point-attached heparin and the other two were non-coated (group B). Under standardized conditions the calves were perfused at a blood flow rate of 2 L/min. After only one bolus injection of heparin (250 IU/kg body weight) before cannulation, plasma heparin activity rapidly decreased in both groups: half life of about 55 minutes This decrease of the heparin activity was accompanied by a fall of the activated clotting time (ACT) level to baseline values. The experiments using a heparin-coated circuit, had a runtime of more than 360 minutes, whereas the experiments using a non-coated circuit had to be terminated after a runtime of 255 minutes, because massive fibrin formation was noticed in the circuit. This formation was accompanied by a rapid increase in the line pressure, measured just before the inlet of the oxygenator. The macroscopic inspections after terminating the experiments and rinsing the circuit showed a clean circuit in group A. The fibrinopeptide A (FPA) level increased faster during perfusion with the non-coated circuit than in the heparin coated circuit. Lung histopathological examinations of the lungs of the animals in group A showed no fibrin deposition, whereas most of the blood vessels of the lung preparations of the animals in group B were partially or completely occluded with fibrin. These results suggest that heparin-bonding greatly reduces the thrombogenicity of the extracorporeal circuit, and therefore it can reduce the need for systemic heparinization in an extracorporeal life support system.
引用
收藏
页码:291 / 298
页数:8
相关论文
共 49 条
[1]   Thrombin generation with heparin-bonded cardiopulmonary bypass circuits [J].
Bannan, S ;
Martin, PG .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 112 (03) :849-849
[2]   TREATMENT OF ACUTE RESPIRATORY-FAILURE BY EXTRACORPOREAL CARBON-DIOXIDE ELIMINATION PERFORMED WITH A SURFACE HEPARINIZED ARTIFICIAL LUNG [J].
BINDSLEV, L ;
EKLUND, J ;
NORLANDER, O ;
SWEDENBORG, J ;
OLSSON, P ;
NILSSON, E ;
LARM, O ;
GOUDA, I ;
MALMBERG, A ;
SCHOLANDER, E .
ANESTHESIOLOGY, 1987, 67 (01) :117-120
[3]  
Bindslev L, 1988, ASAIO Trans, V34, P1009
[4]  
BOISCLAIR MD, 1993, BLOOD, V82, P3350
[5]  
BOISCLAIR MD, 1993, THROMB HAEMOSTASIS, V70, P253
[6]  
BOONSTRA PW, 1994, J THORAC CARDIOV SUR, V107, P289
[7]  
BOSNER RS, 1990, ANN THORAC SURG, V69, P1
[8]   COMPLEMENT ACTIVATION DURING CARDIOPULMONARY BYPASS - EVIDENCE FOR GENERATION OF C3A AND C5A ANAPHYLATOXINS [J].
CHENOWETH, DE ;
COOPER, SW ;
HUGLI, TE ;
STEWART, RW ;
BLACKSTONE, EH ;
KIRKLIN, JW .
NEW ENGLAND JOURNAL OF MEDICINE, 1981, 304 (09) :497-503
[9]  
CHENOWETH DE, 1986, T AM SOC ART INT ORG, V32, P226
[10]   HEPARIN-INDUCED THROMBOCYTOPENIA - MECHANISM OF INTERACTION OF THE HEPARIN-DEPENDENT ANTIBODY WITH PLATELETS [J].
CHONG, BH ;
FAWAZ, I ;
CHESTERMAN, CN ;
BERNDT, MC .
BRITISH JOURNAL OF HAEMATOLOGY, 1989, 73 (02) :235-240