A component based noise correction method (CompCor) for BOLD and perfusion based fMRI

被引:2971
作者
Behzadi, Yashar
Restom, Khaled
Liau, Joy
Liu, Thomas T.
机构
[1] Univ Calif San Diego, Ctr Funct Magnet Resonance Imaging, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Radiol, La Jolla, CA 92093 USA
[3] Univ Calif San Diego, Dept Bioengn, La Jolla, CA 92093 USA
关键词
D O I
10.1016/j.neuroimage.2007.04.042
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
A component based method (CompCor) for the reduction of noise in both blood oxygenation level-dependent (BOLD) and perfusion-based functional magnetic resonance imaging (fMRI) data is presented. In the proposed method, significant principal components are derived from noise regions-of-interest (ROI) in which the time series data are unlikely to be modulated by neural activity. These components are then included as nuisance parameters within general linear models for BOLD and perfusion-based fMRI time series data. Two approaches for the determination of the noise ROI are considered. The first method uses high-resolution anatomical data to define a region of interest composed primarily of white matter and cerebrospinal fluid, while the second method defines a region based upon the temporal standard deviation of the time series data. With the application of CompCor, the temporal standard deviation of resting-state perfusion and BOLD data in gray matter regions was significantly reduced as compared to either no correction or the application of a previously described retrospective image based correction scheme (RETROICOR). For both functional perfusion and BOLD data, the application of CompCor significantly increased the number of activated voxels as compared to no correction. In addition, for functional BOLD data, there were significantly more activated voxels detected with CompCor as compared to RETROICOR. In comparison to RETROICOR, CompCor has the advantage of not requiring external monitoring of physiological fluctuations. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:90 / 101
页数:12
相关论文
共 31 条
  • [1] Probabilistic independent component analysis for functional magnetic resonance imaging
    Beckmann, CF
    Smith, SA
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (02) : 137 - 152
  • [2] Separating respiratory-variation-related neuronal-activity-related fluctuations in fluctuations from fMRI
    Birn, RM
    Diamond, JB
    Smith, MA
    Bandettini, PA
    [J]. NEUROIMAGE, 2006, 31 (04) : 1536 - 1548
  • [3] Reduction of physiological fluctuations in fMRI using digital filters
    Biswal, B
    DeYoe, EA
    Hyde, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) : 107 - 113
  • [4] Linear systems analysis of functional magnetic resonance imaging in human V1
    Boynton, GM
    Engel, SA
    Glover, GH
    Heeger, DJ
    [J]. JOURNAL OF NEUROSCIENCE, 1996, 16 (13) : 4207 - 4221
  • [5] Burock MA, 2000, HUM BRAIN MAPP, V11, P249, DOI 10.1002/1097-0193(200012)11:4<249::AID-HBM20>3.0.CO
  • [6] 2-5
  • [7] AFNI: Software for analysis and visualization of functional magnetic resonance neuroimages
    Cox, RW
    [J]. COMPUTERS AND BIOMEDICAL RESEARCH, 1996, 29 (03): : 162 - 173
  • [8] Localization of cardiac-induced signal change in fMRI
    Dagli, MS
    Ingeholm, JE
    Haxby, JV
    [J]. NEUROIMAGE, 1999, 9 (04) : 407 - 415
  • [9] Glover GH, 2000, MAGNET RESON MED, V44, P162, DOI 10.1002/1522-2594(200007)44:1<162::AID-MRM23>3.0.CO
  • [10] 2-E