Monitoring dioxins in food and feedstuffs using accelerated solvent extraction with a novel integrated carbon fractionation cell in combination with a CAFLUX bioassay

被引:37
作者
Nording, M
Sporring, S
Wiberg, K
Björklund, E
Haglund, P
机构
[1] Swedish Def Res Agcy, S-90182 Umea, Sweden
[2] Umea Univ, Dept Chem, S-90187 Umea, Sweden
[3] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
关键词
aioxin; accelerated solvent extraction; ASE; cell-based bioassay; CAFLUX;
D O I
10.1007/s00216-005-3117-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The concentrations of dioxins in fish oil and fish meal were determined with accelerated solvent extraction, using a novel integrated carbon fractionation extraction cell followed by a miniturized multilayer silica column and bioanalysis on a recently-developed chemically-activated fluorescent gene expression cell bioassay. The developed method allows for simultaneous gravimetric lipid weight determination, which was shown for both matrices under study (about 100% lipid recovery of each sample). Initial results practically meet the quality criteria on screening methods for control of dioxins in food and feedstuffs laid down in the EU Commission Directives 2002/69/EC (food) and 2002/70/EC (feed). This demonstrates that the developed method can be used as a screening tool for monitoring dioxins in food and feed after some additional improvements and testing on a greater number of matrices.
引用
收藏
页码:1472 / 1475
页数:4
相关论文
共 12 条
[1]   Pressurised liquid extraction of persistent organic pollutants in environmental analysis [J].
Björklund, E ;
Nilsson, T ;
Bowadt, S .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (07) :434-445
[2]   Comparison of fat retainers in accelerated solvent extraction for the selective extraction of PCBs from fat-containing samples [J].
Björklund, E ;
Müller, A ;
von Holst, C .
ANALYTICAL CHEMISTRY, 2001, 73 (16) :4050-4053
[3]   Importance of REP values when comparing the CALUX bioassay results with chemoanalyses results - Example with spiked vegetable oils [J].
Carbonnelle, S ;
Van Loco, J ;
Van Overmeire, I ;
Windal, I ;
Van Wouwe, N ;
Van Leeuwen, S ;
Goeyens, L .
TALANTA, 2004, 63 (05) :1255-1259
[4]  
Eskilsson CS, 2000, J CHROMATOGR A, V902, P227
[5]   Comparison of recombinant cell bioassays for the detection of Ah receptor agonists [J].
Han, D ;
Nagy, SR ;
Denison, MS .
BIOFACTORS, 2004, 20 (01) :11-22
[6]   On-line clean-up of pressurized liquid extracts for the determination of polychlorinated biphenyls in feedingstuffs and food matrices using gas chromatography-mass spectrometry [J].
Müller, A ;
Björklund, E ;
von Holst, C .
JOURNAL OF CHROMATOGRAPHY A, 2001, 925 (1-2) :197-205
[7]   Development of a green fluorescent protein-based cell Bioassay for the rapid and inexpensive detection and characterization of Ah receptor agonists [J].
Nagy, SR ;
Sanborn, JR ;
Hammock, BD ;
Denison, MS .
TOXICOLOGICAL SCIENCES, 2002, 65 (02) :200-210
[8]   Identification of novel Ah receptor agonists using a high-throughput green fluorescent protein-rased recombinant cell bioassay [J].
Nagy, SR ;
Liu, G ;
Lam, KS ;
Denison, MS .
BIOCHEMISTRY, 2002, 41 (03) :861-868
[9]   DR-CALUX® screening of food samples:: evaluation of the quantitative approach to measure dioxin, furans and dioxin-like PCBs [J].
Scippo, ML ;
Eppe, G ;
De Pauw, E ;
Maghuin-Rogister, G .
TALANTA, 2004, 63 (05) :1193-1202
[10]   Selective pressurized liquid extraction of polychlorinated biphenyls from fat-containing food and feed samples -: Influence of cell dimensions, solvent type, temperature and flush volume [J].
Sporring, S ;
Björklund, E .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1040 (02) :155-161