Application of tissue Doppler to interpretation of Dobutamine echocardiography and comparison with quantitative coronary angiography

被引:106
作者
Cain, P [1 ]
Baglin, T [1 ]
Case, C [1 ]
Spicer, D [1 ]
Short, L [1 ]
Marwick, TH [1 ]
机构
[1] Univ Queensland, Brisbane, Qld, Australia
基金
英国医学研究理事会;
关键词
D O I
10.1016/S0002-9149(00)01425-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The main limitation of dobutamine echocardiography (DE) is its subjective interpretation. We sought to reduce the need for expert interpretation by developing a quantitative approach to DE using myocardial Doppler velocity (MDV) in 242 patients undergoing DE. In 128 patients with a normal dobutamine echocardiogram, the normal range was designed to give a specificity of 80%. The accuracy of this range was investigated in 114 consecutive patients who underwent coronary angiography within 2 months of DE. A standard dobutamine echocardiographic protocol was used, with MDV gathered from color tissue Doppler at rest and peak stress; Wall motion at these stages was scored by experienced observers using a 16-segment model and MDV was measured off-line. Sensitivity and specificity of wall motion scoring and MDV were obtained by comparison with angiographic evidence of disease, defined as stenosis >50% of the coronary artery diameter. The normal range in tethered segments (septum, anteroseptum, and inferior) was greater than or equal to7 cm/s in the basal segments and greater than or equal to5 cm/s in the midsegments. In the free wall (anterior, lateral, and posterior), the cutoff was greater than or equal to6 cm/s in the base and greater than or equal to4 cm/s in the midventricle. Of 114 patients undergoing angiography, 84 (75%) had significant stenoses, and the sensitivity of wall motion scoring and MDV were 88% and 83%, respectively, with specificities of 81% and 72% (p = NS). The accuracy was similar overall (86% vs 80%), as well as in each vascular territory. These data suggest that a fully quantitative interpretation of DE using site-specific normal ranges of tissue Doppler, which account for regional variations of base-apex function, is feasible and equivalent in accuracy to expert wall motion scoring. (C) 2001 by Excerpta Medica, Inc.
引用
收藏
页码:525 / 531
页数:7
相关论文
共 18 条
  • [1] Stress echocardiography: Recommendations for performance and interpretation of stress echocardiography
    Armstrong, WF
    Pellikka, PA
    Ryan, T
    Crouse, L
    Zoghbi, WA
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (01) : 97 - 104
  • [2] ANALYSIS OF PROBABILITY AS AN AID IN THE CLINICAL-DIAGNOSIS OF CORONARY-ARTERY DISEASE
    DIAMOND, GA
    FORRESTER, JS
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1979, 300 (24) : 1350 - 1358
  • [3] Methodology, feasibility, safety and diagnostic accuracy of dobutamine stress echocardiography
    Geleijnse, ML
    Fioretti, PM
    Roelandt, JRTC
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (03) : 595 - 606
  • [4] QUANTITATIVE-ANALYSIS OF SEGMENTAL WALL MOTION DURING MAXIMAL UPRIGHT DYNAMIC EXERCISE - VARIABILITY IN NORMAL ADULTS
    GINZTON, LE
    CONANT, R
    BRIZENDINE, M
    THIGPEN, T
    LAKS, MM
    [J]. CIRCULATION, 1986, 73 (02) : 268 - 275
  • [5] Objective echocardiographic evaluation of the cardiovascular system: state of the art
    Godoy, IE
    MorAvi, V
    Spencer, KT
    Lang, RM
    [J]. CURRENT OPINION IN CARDIOLOGY, 1997, 12 (06) : 553 - 560
  • [6] Quantification of the myocardial response to low-dose Dobutamine using tissue Doppler echocardiographic measures of velocity and velocity gradient
    Gorcsan, J
    Deswal, A
    Mankad, S
    Mandarino, WA
    Mahler, CM
    Yamazaki, N
    Katz, WE
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (05) : 615 - 623
  • [7] Real-time strain rate imaging of the left ventricle by ultrasound
    Heimdal, A
    Stoylen, A
    Torp, H
    Skjaerpe, T
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (11) : 1013 - 1019
  • [8] Analysis of interinstitutional observer agreement in interpretation of dobutamine stress echocardiograms
    Hoffmann, R
    Lethen, H
    Marwick, T
    Arnese, M
    Fioretti, P
    Pingitore, A
    Picano, E
    Buck, T
    Erbel, R
    Flachskampf, FA
    Hanrath, P
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (02) : 330 - 336
  • [9] Echocardiographic quantification of regional left ventricular wall motion with color kinesis
    Lang, RM
    Vignon, P
    Weinert, L
    Bednarz, J
    Korcarz, C
    Sandelski, J
    Koch, R
    Prater, D
    MorAvi, V
    [J]. CIRCULATION, 1996, 93 (10) : 1877 - 1885
  • [10] ENHANCED SENSITIVITY FOR DETECTION OF CORONARY-ARTERY DISEASE BY ADDITION OF ATROPINE TO DOBUTAMINE STRESS ECHOCARDIOGRAPHY
    MCNEILL, AJ
    FIORETTI, PM
    ELSAID, ESM
    SALUSTRI, A
    FORSTER, T
    ROELANDT, JRTC
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (01) : 41 - 46