Comparison of the Batho, ETAR and Monte Carlo dose calculation methods in CT based patient models

被引:34
作者
du Plessis, FCP
Willemse, CA
Lötter, MG
Goedhals, L
机构
[1] Univ Orange Free State, Dept Phys Med, Fac Hlth Sci, ZA-9300 Bloemfontein, South Africa
[2] Natl Hosp, Dept Radiat Oncol, ZA-9301 Bloemfontein, South Africa
关键词
Monte Carlo; CT data; patient dose distribution; x-ray energy; field size; beam; DOSXYZ;
D O I
10.1118/1.1357223
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This paper shows the contribution that Monte Carlo methods make in regard to dose distribution calculations in CT based patient models and the role it plays as a gold standard to evaluate other dose calculation algorithms. The EGS4 based BEAM code was used to construct a generic 8 MV accelerator to obtain a series of x-ray field sources. These were used in the EGS4 based DOSXYZ code to generate beam data in a mathematical water phantom to set up a beam model in a commercial treatment planning system (TPS), CADPLAN V.2.7.9. Dose distributions were calculated with the Bathe and ETAR inhomogeneity correction algorithms in head/sinus, lung, and prostate patient models for 2X 2, 5X5, and 10X10 cm(2) open x-ray beams. Corresponding dose distributions were calculated with DOSXYZ that were used as a benchmark. The dose comparisons are expressed in terms of 2D isodose distributions, percentage depth dose data, and dose difference volume histograms (DDVH's). Results indicated that the Bathe and ETAR methods contained inaccuracies of 20%-70% in the maxillary sinus region in the head model. Large lung inhomogeneities irradiated with small fields gave rise to absorbed dose deviations of 10%-20%. It is shown for a 10X10 cm(2) field that DOSXYZ models lateral scatter in lung that is not present in the Batho and ETAR methods. The ETAR and Bathe methods are accurate within 3% in a prostate model. We showed how the performance of these inhomogeneity correction methods can be understood in realistic patient models using validated Monte Carlo codes such as BEAM and DOSXYZ. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:582 / 589
页数:8
相关论文
共 33 条
[1]   CALCULATION AND APPLICATION OF POINT SPREAD FUNCTIONS FOR TREATMENT PLANNING WITH HIGH-ENERGY PHOTON BEAMS [J].
AHNESJO, A ;
ANDREO, P ;
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (01) :49-56
[2]   DOSIMETRIC PRECISION REQUIREMENTS IN RADIATION-THERAPY [J].
BRAHME, A .
ACTA RADIOLOGICA ONCOLOGY, 1984, 23 (05) :379-391
[3]   SCATTER-AIR RATIOS [J].
CUNNINGHAM, JR .
PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (01) :42-+
[4]   CT-based Monte Carlo simulation tool for dosimetry planning and analysis [J].
DeMarco, JJ ;
Solberg, TD ;
Smathers, JB .
MEDICAL PHYSICS, 1998, 25 (01) :1-11
[5]   The indirect use of CT numbers to establish material properties needed for Monte Carlo calculation of dose distributions in patients [J].
du Plessis, FCP ;
Willemse, CA ;
Lotter, MG ;
Goedhals, L .
MEDICAL PHYSICS, 1998, 25 (07) :1195-1201
[6]   IMPROVED LUNG DOSE CALCULATION USING TISSUE MAXIMUM RATIOS IN THE BATHO CORRECTION [J].
ELKHATIB, E ;
BATTISTA, JJ .
MEDICAL PHYSICS, 1984, 11 (03) :279-286
[7]   ACCURACY OF LUNG DOSE CALCULATIONS FOR LARGE-FIELD IRRADIATION WITH 6-MV X-RAYS [J].
ELKHATIB, E ;
BATTISTA, JJ .
MEDICAL PHYSICS, 1986, 13 (01) :111-116
[8]  
HALBLEIB JA, 1992, 840073 SAN SAND NAT
[9]  
Hartmann Siantar C. L., 1995, Proceedings of the International Conference, Mathematics and Computations, Reactor Physics, and Environmental Analyses, P857
[10]  
International Commission on Radiation Units and Measurements (ICRU), 1989, TISS SUBS RAD DOS ME