Three-dimensional study of the effect of two leaflet opening angles on the time-dependent flow through a bileaflet mechanical heart valve

被引:33
作者
King, MJ
David, T
Fisher, J
机构
[1] Department of Mechanical Engineering, University of Leeds
基金
英国惠康基金;
关键词
CarboMedics; St; Jude; computational fluid dynamics; CFD; numerical; model; heart valve; time-dependent; three-dimensional;
D O I
10.1016/S1350-4533(96)00066-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A three-dimensional (3-D), time-dependent computational fluid dynamics (CFD) model was used to investigate the effect Of leaflet opening angle on the flow through a Sully open bileaflet heart valve up to peak systole. A laminar pow model of a Newtonian fluid was used, and the peak systolic Reynolds number was 1500, based on the aortic radius and the average velocity at peak systole. This resulted in a Reynolds number of 5800, based on the aortic radius and the local maximum velocity. The flow fields through and downstream of the bileaflet valves were complex, with strong time-dependent 3-D vortices being found in planes parallel and perpendicular to the leaflets. The parametric study of the effect of leaflet opening angle showed that, as the leaflet opening angle increased from 78 degrees to 85 degrees, the flow downstream of the valve leaflets became more centralized, and the wake downstream of the leaflet decreased in size. However, as the opening angle increased from 78 degrees to 85 degrees, the maximum shear rate and the maximum velocity increased suggesting that the design of the central orifice geometry was also an important consideration. (C) 1997 Elsevier Science Ltd for IPEM.
引用
收藏
页码:235 / 241
页数:7
相关论文
共 13 条
[1]  
Black M M, 1994, J Heart Valve Dis, V3, P212
[2]   A SQUEEZE FLOW PHENOMENON AT THE CLOSING OF A BILEAFLET MECHANICAL HEART-VALVE PROSTHESIS [J].
BLUESTEIN, D ;
EINAV, S ;
HWANG, NHC .
JOURNAL OF BIOMECHANICS, 1994, 27 (11) :1369-1378
[3]   A NEW THEORETICAL-MODEL FOR NONINVASIVE QUANTIFICATION OF MITRAL REGURGITATION [J].
CAPE, EG ;
YOGANATHAN, AP ;
LEVINE, RA .
JOURNAL OF BIOMECHANICS, 1990, 23 (01) :27-33
[4]  
CHANDRAN KB, 1985, J THORAC CARDIOV SUR, V89, P743
[5]   AN INVITRO COMPARATIVE-STUDY OF ST-JUDE MEDICAL AND EDWARDS-DUROMEDICS BILEAFLET VALVES USING LASER ANEMOMETRY [J].
FATEMI, R ;
CHANDRAN, KB .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1989, 111 (04) :298-302
[6]  
GROSS JM, 1988, T AM SOC ART INT ORG, V34, P845
[7]  
King M. J., 1994, Proceedings of the Institution of Mechanical Engineers, Part H (Journal of Engineering in Medicine), V208, P63, DOI 10.1243/PIME_PROC_1994_208_267_02
[8]   A three-dimensional, time-dependent analysis of flow through a bileaflet mechanical heart valve: Comparison of experimental and numerical results [J].
King, MJ ;
Corden, J ;
David, T ;
Fisher, J .
JOURNAL OF BIOMECHANICS, 1996, 29 (05) :609-618
[9]  
KING MJ, 1994, TEHSIS U LEEDS UK
[10]  
LEI M, 1991, J BIOMECH, V3, P213