A knee and ankle flexing hybrid orthosis for paraplegic ambulation

被引:30
作者
Greene, PJ [1 ]
Granat, MH [1 ]
机构
[1] Univ Strathclyde, Bioengn Unit, Wolfson Ctr, Glasgow G4 0NW, Lanark, Scotland
关键词
knee flexion; ankle flexion; paraplegic ambulation; hybrid orthosis;
D O I
10.1016/S1350-4533(03)00072-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Limitations of mechanical walking orthoses for paraplegics are high energy consumption and upper limb loading. Flexing of the knee during swing phase has been used as a means of attempting to reduce these: It has been found that this has little effect because using knee flexion results in no change in the compensatory mechanisms required for swing foot clearance. This is because knee flexion can result in an increase in effective leg length, i.e. hip to toe distance. A combination of knee flexion and ankle dorsiflexion during swing phase is suggested as a means of reducing compensatory mechanisms. To examine this hypothesis, an orthosis incorporating knee and ankle flexion was constructed. The design used a novel mechanism to link the motion of the knee to that of the ankle, and also used functional electrical stimulation. Two spinal cord-injured subjects were trained to use the orthosis in two configurations. The first configuration used knee flexion and ankle dorsiflexion and the second configuration used knee flexion alone. Kinematic data were obtained to measure the compensatory mechanisms used during gait. The results showed that a combination of knee flexion and ankle dorsiflexion during swing phase resulted in a reduction in compensatory mechanisms when compared with knee flexion alone. (C) 2003 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:539 / 545
页数:7
相关论文
共 9 条
[1]
BAARDMAN G, 1996, DESIGN EVALUATION HY, P73
[2]
EDWARDS J, 1996, NEUROPROSTHETICS BAS, P523
[3]
The effects of knee and ankle flexion on ground clearance in paraplegic gait [J].
Greene, PJ ;
Granat, MH .
CLINICAL BIOMECHANICS, 2000, 15 (07) :536-540
[4]
AMBULATION USING THE RECIPROCATING GAIT ORTHOSIS AND FUNCTIONAL ELECTRICAL-STIMULATION [J].
ISAKOV, E ;
DOUGLAS, R ;
BERNS, P .
PARAPLEGIA, 1992, 30 (04) :239-245
[5]
ORTHOPEDIC MANAGEMENT OF HIGH-LEVEL SPINA-BIFIDA - EARLY WALKING COMPARED WITH EARLY USE OF A WHEELCHAIR [J].
MAZUR, JM ;
SHURTLEFF, D ;
MENELAUS, M ;
COLLIVER, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (01) :56-61
[6]
ROSE GK, 1979, PROSTHET ORTHOT INT, V3, P37
[7]
SOLOMONOW M, 1989, ORTHOPEDICS, V12, P1309
[8]
THE RECIPROCATING GAIT ORTHOSIS - LONG-TERM USAGE PATTERNS [J].
SYKES, L ;
EDWARDS, J ;
POWELL, ES ;
ROSS, ERS .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1995, 76 (08) :779-783
[9]
Effects of joint motion constraints on the gait of normal subjects and their implications on the further development of hybrid FES orthosis for paraplegic persons [J].
Yang, L ;
Condie, DN ;
Granat, MH ;
Paul, JP ;
Rowley, DI .
JOURNAL OF BIOMECHANICS, 1996, 29 (02) :217-226