Comparison between wire-mesh sensor and ultra-fast X-ray tomograph for an air-water flow in a vertical pipe

被引:140
作者
Prasser, HM
Misawa, M
Tiseanu, I
机构
[1] Rossendorf Inc, Forschungszentrum Rossendorf EV, Inst Safety Res, D-01314 Dresden, Germany
[2] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki 3058564, Japan
[3] Inst Atom Phys, INFLPR Lab 22, R-76900 Bucharest, Romania
关键词
two-phase flow; X-ray tomography; wire-mesh sensor; gas fraction distribution; bubble flow; slug flow;
D O I
10.1016/j.flowmeasinst.2005.02.003
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A comparison between ultra-fast X-ray CT and a wire-mesh sensor is presented. The measurements were carried out in a vertical pipe of 42 nun inner diameter. which was supplied with an air-water mixture. Both gas and liquid superficial velocities were varied. The X-ray CT delivered 263 frames per second, while the wire-mesh sensor was operated at a frequency four times higher. Two different gas injectors were used: four orifices of 5 mm diameter for creating large bubbles and gas plugs and a sintered plate with a pore size of 100 mu m for generating a bubbly flow. It was found that the wire-mesh sensor has a significantly higher resolution than the X-ray CT. Small bubbles, which are clearly shown by the wire-mesh sensor, cannot be found in the CT images, because they cross the measuring plane before a complete scan can be performed. This causes artifacts in the reconstructed images, instead. Furthermore, there are large deviations between the quantitative information contained in the reconstructed tomographic 2D distributions and the gas fractions measured by the sensor, while the agreement is very good when the gas fraction is obtained by a direct evaluation of the X-ray attenuation along the available through-transmission chords of the tomography set-up. This shows that there is still potential for an improvement of the image reconstruction method. Concerning the wire-mesh sensor it was found that the gas fraction inside large bubbles is slightly underestimated. Furthermore, a significant distortion of large Taylor bubbles by the sensor was found for small liquid velocities up to 0.24 m/s. This effect vanished with growing superficial water velocity. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:73 / 83
页数:11
相关论文
共 19 条
[1]  
FROYSTEIN T, 1997, SYSTEMS P FRONTIERS, P185
[2]  
Gondrom S., 1999, P COMPUTERIZED TOMOG
[3]   Application of cadmium telluride detector to high speed X-ray CT scanner [J].
Hori, K ;
Fujimoto, T ;
Kawanishi, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :397-401
[4]  
Hori K., 1993, GRAPHIC SIMULATION V, V21, P96
[5]  
Johnson I D, 1987, United States Patent, Patent No. [4,644,263, 4644263]
[6]   Application of fast X-ray CT scanner to visualization of bubbles in fluidized bed [J].
Kai, T ;
Misawa, M ;
Takahashi, T ;
Tiseanu, I ;
Ichikawa, N ;
Takada, N .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2000, 33 (06) :906-909
[7]   A GAMMA-RAY TOMOGRAPHIC SCANNER FOR IMAGING VOIDAGE DISTRIBUTION IN 2-PHASE FLOW SYSTEMS [J].
KUMAR, SB ;
MOSLEMIAN, D ;
DUDUKOVIC, MP .
FLOW MEASUREMENT AND INSTRUMENTATION, 1995, 6 (01) :61-73
[8]  
Marmeggi J.C., 2002, J MICROELECTRONICS E, V1
[9]  
Misawa M., 2003, Kerntechnik, V68, P85
[10]  
MISAWA M, 1998, P 6 INT C NUCL ENG