Morphometry of the proximal tibia to design the tibial component of total knee arthroplasty for the Korean population

被引:129
作者
Kwak, Dai Soon
Surendran, Sibin
Pengatteeri, Yassir Hussain
Park, Sang Eun
Choi, Kwang Nam
Gopinathan, Patinharayil
Han, Seung Ho
Han, Chang Whan
机构
[1] Catholic Univ Korea, Catholic Inst Appl Anat, Seoul 137701, South Korea
[2] Himchan Hosp, Dept Orthoped, Inchon 406818, South Korea
[3] Korea Inst Sci & Technol Informat, Taejon, South Korea
关键词
proximal tibia anthropometry; prostheses mismatch; cadaveric study; computer tomography;
D O I
10.1016/j.knee.2007.05.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We carried Out an anthropometric analysis using three dimensional computer tomographic measurements of the cut surface of the proximal tibia in 200 knees that were obtained from 50 male and 50 female Korean cadavers. We measured the mediolateral (ML), middle anteroposterior (AP), medial and lateral anteroposterior dimensions and the aspect ratio (ML/AP) of the resected proximal tibial surface; we then compared this data with the five conventionally used symmetric total knee components. We found that the ML (73.5 +/- 5.6 mm) and AP (47.3 +/- 3.8 mm) average dimensions of our study population were smaller than the dimensions of the symmetric commercially available TKA implants. We found a progressive decrease in the aspect ratio with the increasing anteroposterior dimension of the proximal tibia, as compared to the constant aspect ratio shown by the conventional tibial prostheses. The smaller sized prostheses were found to show mediolateral undersizing and the larger sized prostheses were found to show mediolateral overhang. This study may provide guidelines for designing a suitable tibial component of total knee prostheses for the Korean population, the aspect ratio of which decreases with increasing anteroposterior dimension. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:295 / 300
页数:6
相关论文
共 13 条
[1]  
BLOEBAUM RD, 1994, CLIN ORTHOP RELAT R, P2
[2]  
Canale ST., 2003, CAMPBELLS OPERATIVE, P292
[3]   Anthropometric measurements of the human knee: Correlation to the sizing of current knee arthroplasty systems [J].
Hitt, K ;
Shurman, JR ;
Greene, K ;
McCarthy, J ;
Moskal, J ;
Hoeman, T ;
Mont, MA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A :115-122
[4]  
INCAVO SJ, 1994, CLIN ORTHOP RELAT R, P81
[5]  
INSALL JN, 1989, CLIN ORTHOP RELAT R, P13
[6]  
MENSCH JS, 1975, CLIN ORTHOP RELAT R, P231
[7]  
STULBERG BN, 1995, CLIN ORTHOP RELAT R, P148
[8]   Anthropometry of the proximal tibia to design a total knee prosthesis for the Japanese population [J].
Uehara, K ;
Kadoya, Y ;
Kobayashi, A ;
Ohashi, H ;
Yamano, Y .
JOURNAL OF ARTHROPLASTY, 2002, 17 (08) :1028-1032
[9]   Anthropometric measurements to design total knee prostheses for the Indian population [J].
Vaidya, SV ;
Ranawat, CS ;
Aroojis, A ;
Laud, NS .
JOURNAL OF ARTHROPLASTY, 2000, 15 (01) :79-85
[10]  
Westrich G H, 1995, J Arthroplasty, V10, P47