Comparison of automatic and patient-activated arrhythmia recordings by implantable loop recorders in the evaluation of syncope

被引:44
作者
Ermis, C
Zhu, AX
Pham, S
Li, JM
Guerrero, M
Vrudney, A
Hiltner, L
Lu, F
Sakaguchi, S
Lurie, KG
Benditt, DG
机构
[1] Univ Minnesota, Sch Med, Cardiac Arrhythmia Ctr, Minneapolis, MN 55455 USA
[2] Vet Adm Med Ctr, Minneapolis, MN 55417 USA
[3] Hennepin Cty Med Ctr, Minneapolis, MN 55415 USA
[4] St Cloud Hosp, Cent Minnesota Heart Ctr, St Cloud, MN USA
关键词
D O I
10.1016/S0002-9149(03)00889-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The implantable loop recorder (ILR) has become an important tool for evaluating patients with recurrent syncope. Second generation ILRs have the ability to record events either automatically (auto activated) or by manual activation (patient activated). In an attempt to evaluate the relative utility of the auto-activation feature, this study stratified ILR events based on a grading system designed to classify detected arrhythmias in terms of the likelihood that they provide a diagnostic basis for syncope. Data from 50 patients (27 men, mean age 64 22 years) who underwent ILR implantation for investigation of recurrent syncope were assessed. The arrhythmia syncope grading system used 5 levels, ranging from grade 0 (rhythm recorded during syncope) to grade IV (rhythm unlikely to provide a diagnostic basis for syncope). Thirty-six patients (72%) demonstrated greater than or equal to1 autoactivated or patient-activated recording during a follow-up of 14.3 +/- 7.9 months. Of the total of 529 recordings, 223 (194 after auto activation [86.9%]) from 30 patients showed a rhythm abnormality. Auto activation was more effective for documenting arrhythmias that were recorded during syncope or those with highest probability of providing a syncope diagnosis (grade 0 or I arrhythmias: auto activated, 19 patients, patient activated, 3 patients). Times from ILR implantation to first grade 0 and grade 1 arrhythmias were 13.4 and 7.8 months, respectively. The ILR auto-activation feature proved effective in providing a high probability basis for syncope (196 arrhythmia recordings [87.1%] in 27 patients) and enhanced the diagnostic effectiveness of the device compared with patient activation alone (29 arrhythmia recordings [12.9%] in 6 patients). (C) 2003 by Excerpta Medica, Inc.
引用
收藏
页码:815 / 819
页数:5
相关论文
共 7 条
[1]   Guidelines on management (diagnosis and treatment) of syncope [J].
Brignole, M ;
Alboni, P ;
Benditt, D ;
Bergfeldt, L ;
Blanc, JJ ;
Thomsen, PEB ;
van Dijk, JG ;
Fitzpatrick, A ;
Hohnloser, S ;
Janousek, J ;
Kapoor, W ;
Kenny, RA ;
Kulakowski, P ;
Moya, A ;
Raviele, A ;
Sutton, R ;
Theodorakis, G ;
Wieling, W .
EUROPEAN HEART JOURNAL, 2001, 22 (15) :1256-1306
[2]   Mechanism of syncope in patients with bundle branch block and negative electrophysiological test [J].
Brignole, M ;
Menozzi, C ;
Moya, A ;
Garcia-Civera, R ;
Mont, L ;
Alvarez, M ;
Errazquin, F ;
Beiras, J ;
Bottoni, N ;
Donateo, P .
CIRCULATION, 2001, 104 (17) :2045-2050
[3]   Final results from a pilot study with an implantable loop recorder to determine the etiology of syncope in patients with negative noninvasive and invasive testing [J].
Krahn, AD ;
Klein, GJ ;
Yee, R ;
Norris, C .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (01) :117-119
[4]   Use of an extended monitoring strategy in patients with problematic syncope [J].
Krahn, AD ;
Klein, GJ ;
Yee, R ;
Takle-Newhouse, T ;
Norris, C .
CIRCULATION, 1999, 99 (03) :406-410
[5]   Randomized assessment of syncope trial - Conventional diagnostic testing versus a prolonged monitoring strategy [J].
Krahn, AD ;
Klein, GJ ;
Yee, R ;
Skanes, AC .
CIRCULATION, 2001, 104 (01) :46-51
[6]   Mechanism of syncope in patients with heart disease and negative electrophysiologic test [J].
Menozzi, C ;
Brignole, M ;
Garcia-Civera, R ;
Moya, A ;
Botto, G ;
Tercedor, L ;
Migliorini, R ;
Navarro, X .
CIRCULATION, 2002, 105 (23) :2741-2745
[7]   Mechanism of syncope in patients with isolated syncope and in patients with tilt-positive syncope [J].
Moya, A ;
Brignole, M ;
Menozzi, C ;
Garcia-Civera, R ;
Tognarini, S ;
Mont, L ;
Botto, G ;
Giada, F ;
Cornacchia, D .
CIRCULATION, 2001, 104 (11) :1261-1267