Comparison of pathologist-detected and automated computer-assisted image analysis detected sentinel lymph node micrometastases in breast cancer

被引:47
作者
Weaver, DL
Krag, DN
Manna, EA
Ashikaga, T
Harlow, SP
Bauer, KD
机构
[1] Univ Vermont, Coll Med, Dept Pathol, Vermont Canc Ctr & Fletcher Allen Hlth Care, Burlington, VT 05405 USA
[2] ChromaVis Med Syst, San Juan Capistrano, CA USA
关键词
breast cancer; cytokeratin; image analysis; immunohistochemistry; micrometastases; sentinel lymph nodes;
D O I
10.1097/01.MP.0000092952.21794.AD
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Sentinel lymph node biopsy has stimulated interest in identification of micrometastatic disease in lymph nodes, but identifying small clusters of tumor cells or single tumor cells in lymph nodes can be tedious and inaccurate. The optimal method of detecting micrometastases in sentinel nodes has not been established. Detection is dependent on node sectioning strategy and the ability to locate and confirm tumor cells on histologic sections. Immunohistochemical techniques have greatly enhanced detection in histologic sections; however, comparison of detection methodology has not been undertaken. Automated computer-assisted detection of candidate tumor cells may have the potential to significantly assist the pathologist. This study compares computer-assisted micrometastasis detection with routine detection by a pathologist. Cytokeratin-stained sentinel lymph node sections from 100 patients at the University of Vermont were evaluated by automated computer-assisted cell detection. Based on original routine light microscopy screening, 20 cases that were positive and 80 cases that were negative for micrometastases were selected. One-level (43 cases) or two-level (54 cases) cytokeratin-stained sections were examined per lymph node block All 100 patients had previously been classified as node negative by using routine hematoxylin and eosin stained sections. Technical staining problems precluded computer-assisted cell detection scanning in three cases. Computer-assisted cell detection detected 19 of 20 (95.0%; 95% confidence interval, 75-100%) cases positive by routine light microscopy. Micrometastases missed by computer-assisted cell detection were caused by cells outside the instruments scanning region. Computer-assisted cell detection detected additional micrometastases, undetected by light microscopy, in 8 of 77 (10.4%; 95% confidence interval, 5-20%) cases. The computer-assisted cell detection-positive, light microscopy-missed detection rate was similar for cases with one (3 of 30; 10.0%) or two (5 of 47; 10.6%) cytokeratin sections. Metastases detected by routine light microscopy tended to be larger (0.01-0.50 mm) than did metastases detected only by computer-assisted cell detection (0.01-0.03 mm). In a selected series of patients, automated computer-assisted cell detection identified more micrometastases than were identified by routine light microscopy screening of cytokeratin-stained sections. Computer-assisted detection of events that are limited in number or size may be more reliable than detection by a pathologist using routine fight microscopy. Factors such as human fatigue, incomplete section screening, and variable staining contribute to missing metastases by routine light microscopy screening. Metastases identified exclusively by computer-assisted cell detection tend to be extremely small, and the clinical significance of their identification is currently unknown.
引用
收藏
页码:1159 / 1163
页数:5
相关论文
共 21 条
[1]   Lymphatic mapping and sentinel node biopsy in the patient with breast cancer [J].
Albertini, JJ ;
Lyman, GH ;
Cox, C ;
Yeatman, T ;
Balducci, L ;
Ku, NN ;
Shivers, S ;
Berman, C ;
Wells, K ;
Rapaport, D ;
Shons, A ;
Horton, J ;
Greenberg, H ;
Nicosia, S ;
Clark, R ;
Cantor, A ;
Reintgen, DS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (22) :1818-1822
[2]   Early distant relapse in 'node-negative' breast cancer patients is not predicted by occult axillary lymph node metastases, but by the features of the primary tumour [J].
Colpaert, C ;
Vermeulen, P ;
Jeuris, W ;
van Beest, P ;
Goovaerts, G ;
Weyler, J ;
Van Dam, P ;
Dirix, L ;
Van Marck, E .
JOURNAL OF PATHOLOGY, 2001, 193 (04) :442-449
[3]   Role of immunohistochemical detection of lymph-node metastases in management of breast cancer [J].
Cote, RJ ;
Peterson, HF ;
Chaiwun, B ;
Gelber, RD ;
Goldhirsch, A ;
Castiglione-Gertsch, M ;
Gusterson, B ;
Neville, AM .
LANCET, 1999, 354 (9182) :896-900
[4]   Occult metastases in sentinel nodes of 200 patients with operable breast cancer [J].
Dowlatshahi, K ;
Fan, M ;
Anderson, JM ;
Bloom, KJ .
ANNALS OF SURGICAL ONCOLOGY, 2001, 8 (08) :675-681
[5]  
FISHER ER, 1978, CANCER, V42, P2032, DOI 10.1002/1097-0142(197810)42:4<2032::AID-CNCR2820420453>3.0.CO
[6]  
2-O
[7]  
Fitzgibbons PL, 2000, ARCH PATHOL LAB MED, V124, P966
[8]  
Fleming ID, 1997, AJCC CANC STAGING MA, P171
[9]   LYMPHATIC MAPPING AND SENTINEL LYMPHADENECTOMY FOR BREAST-CANCER [J].
GIULIANO, AE ;
KIRGAN, DM ;
GUENTHER, JM ;
MORTON, DL .
ANNALS OF SURGERY, 1994, 220 (03) :391-401
[10]  
Greene FL., 2002, AJCC CANC STAGING HD, V6th