Screening method for phthalate esters in water using liquid-phase microextraction based on the solidification of a floating organic microdrop combined with gas chromatography-mass spectrometry

被引:118
作者
Farahani, Hadi [1 ]
Ganjali, Mohammad Reza [1 ,2 ]
Dinarvand, Rassoul [3 ]
Norouzi, Parviz [1 ,2 ]
机构
[1] Univ Tehran, Ctr Excellence Electrochem, Fac Chem, Tehran, Iran
[2] Univ Tehran Med Sci, Endocrinol & Metab Res Ctr, Tehran, Iran
[3] Univ Tehran Med Sci, Med Nanotechnol Res Ctr, Tehran, Iran
关键词
liquid-phase microextraction (LPME); phthalate esters; gas chromatography-mass spectrometry (GC-MS); water samples;
D O I
10.1016/j.talanta.2008.03.002
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
A simple and efficient liquid-phase microextraction (LPME) technique was developed using directly suspended organic microdrop coupled with gas chromatography-mass spectrometry (GC-MS), for the extraction and the determination of phthalate esters (dimethyl phthalate, diethyl phthalate, diallyl phthalate, di-n-butyl phthalate (DnBP), benzyl butyl phthalate (BBP), dicyclohexyl phthalate and di-2-ethylhexyl phthalate (DEHP)) in water samples. Microextraction efficiency factors, such as nature and volume of the organic solvent, temperature, salt effect, stirring rate and the extraction time were investigated and optimized. Under the optimized extraction conditions (extraction solvent: 1-dodecanol; extraction temperature: 60 degrees C; microdrop volume: 7 mu L; stirring rate: 750 rpm, without salt addition and extraction time: 25 min), figures of merit of the proposed method were evaluated. The values of the detection limit were in the range of 0.02-0.05 mu g L(-1), while the R.S.D.% value for the analysis of 5.0 mu g L(-1) of the analytes was below 7.7% (n = 4). A good linearity (r(2) >= 0.9940) and a broad linear range (0.05-100 mu g L(-1)) were obtained. The method exhibited enrichment factor values ranging from 307 to 412. Finally, the designed method was successfully applied for the preconcentration and determination of the studied phthalate esters in different real water samples and satisfactory results were attained. (C) 2008 Published by Elsevier B.V.
引用
收藏
页码:718 / 723
页数:6
相关论文
共 52 条
[1]
[Anonymous], TRENDS ANAL CHEM
[2]
[Anonymous], 1991, FED REG
[3]
SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[4]
Immersed solvent microextraction and gas chromatography-mass spectrometric detection of s-triazine herbicides in aquatic media [J].
Bagheri, H ;
Khalilian, F .
ANALYTICA CHIMICA ACTA, 2005, 537 (1-2) :81-87
[5]
Immersed solvent microextraction of phenol and chlorophenols from water samples followed by gas chromatography-mass spectrometry [J].
Bagheri, H ;
Saber, A ;
Mousavi, SR .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1046 (1-2) :27-33
[6]
Bartulewicz J, 1996, CHEM ANAL-WARSAW, V41, P753
[7]
Application of single-drop microextraction to the determination of dialkyl phthalate esters in food simulants [J].
Batlle, R ;
Nerín, C .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1045 (1-2) :29-35
[8]
Monosegmented micro-volume liquid-liquid flow-extraction system based on intermittent pumping and spectroscopic detection [J].
Carlsson, K ;
Karlberg, B .
ANALYTICA CHIMICA ACTA, 2000, 415 (1-2) :1-7
[9]
Evaluation of ELISA kits followed by liquid chromatography atmospheric pressure chemical ionization mass spectrometry for the determination of organic pollutants in industrial effluents [J].
Castillo, M ;
Oubina, A ;
Barcelo, D .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1998, 32 (14) :2180-2184
[10]
Castillo M, 1997, J MASS SPECTROM, V32, P1100, DOI 10.1002/(SICI)1096-9888(199711)32:10<1100::AID-JMS564>3.3.CO